泰亚赛福 —— 工业设备集采平台
努力为您创造价值
智能 编号 品牌
 您当前的位置:首页 >> 品牌 >> Molecular Devices >> 酶标仪
产品目录
品牌简介

  美国Molecular Devices Corporation(MDC)公司成立于1983年,位于美国高科技密集的加里佛尼亚州,是一家致力于为生命科学和药物研发工作者提供专业的、高精度、高通量、高性能的微孔板测读分析仪和液体操作系统的厂商。拥有该领域的上百项专利技术,系列产品已被广泛应用于药物筛选、分子生物学、免疫学、细胞学、生物化学、电生理学等多个领域,是微孔板测读分析领域的国际第一品牌。总部位于美国硅谷,在英国、德国、挪威、韩国和日本均设有分支机构。2005年美国分子仪器公司正式进驻中国。

>>品牌详情

推荐产品
热销产品

Reader M3多功能酶标仪

2011/3/12 18:27:43 阅读:1583次

  • 产品系列名称:Reader M3多功能酶标仪
  • 产品定货号:ML-14478-00
  • 产地:美国
  • 品牌:Molecular Devices
  • 推荐:
Provides three modes of detection in a multi-mode system with the upgrade option to add TRF, FP, and HTRF modes at a later time. Your applications, your modes, your choice.
The SpectraMax® M3 Multi-Mode Microplate Reader dual monochromatic optics allows the widest range of applications to be utilized for bioresearch applications all without the need to change filters, and provides three modes of detection in one platform.
  • UV-Visible Absorbance (Abs)
  • Fluorescence Intensity (FI)
  • Glow Luminescence (Lumi)
The SpectraMax M3 Microplate Reader is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-, and 384-well microplates.
Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax M3 Microplate Reader transforms each well in a microplate to a fixed optical path length cuvette, and can eliminate standard curves by allowing the calculation of concentrations directly from the absorbance with a known extinction co-efficient, as exemplified with nucleic acid and protein quantification
For fluorescence intensity assays users can select from top or bottom read modes for improved sensitivity for solution and cell-based assays. Assays can be better optimized by scanning across a range of wavelengths in increments as small as 1 nm. Up to 4 wavelength pairs can be read in one protocol for endpoint and kinetic measurements allowing for fast setup of FRET assays.
For luminescence, the SpectraMax M3 Microplate Reader utilizes a dedicated luminescence photomultiplier tube (PMT), providing the user the maximum signal and lowest background possible for glow luminescence reporter gene assays.
If the needs of the researcher change, the SpectraMax M3 Microplate Reader can be upgraded with more detection options including time-resolved fluorescence, fluorescence polarization, and HTRF certified detection making it equivalent to the SpectraMax M4 Microplate Reader, SpectraMax M5 Microplate Reader, or the SpectraMax M5e Microplate Reader.
The SpectraMax M3 Microplate Reader is supplied with SoftMax Pro Data Acquisition & Analysis Software, Molecular Devices' industry leading all-in-one software. Additionally, the SpectraMax M3 Microplate Reader can be seamlessly integrated with the StakMax® Microplate Handling System through SoftMax Pro Data Acquisition & Analysis Software.
 
Multiple Detection Modes: The optics in the SpectraMax M3 Microplate Reader is designed to easily adapt to changes in assay requirements while maintaining the optimal performance for all modes including absorbance, fluorescence intensity, and luminescence.
Precision Optics and Detectors: The SpectraMax M3 Microplate Reader utilizes several key technologies to ensure optimal sensitivity for all modes.
  • Dual monochromators allow users to target the optimal assay excitation and emission wavelengths and eliminate the need to change expensive band pass filters between experiments
  • Dual photomultiplier tubes (PMTs) provide detection flexibility to the widest variety of assays
  • Reference diodes automatically adjust to slight fluctuations in excitation intensity to reduce measurement noise
  • Absorbance applications are enhanced using top-quality UV grade fibers to provide strong light transmission in the lowest wavelengths
Patented AutoPMT Optimization System: Unlike most fluorescence readers that may saturate with signal intensities over 3 orders of magnitude, the patented AutoPMT Optimization System of the SpectraMax M3 Microplate Reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays so that low, medium, and high signals can be captured from the same plate. This calibration against an internal standard provides an additional benefit in being able to confidently compare relative fluorescence units (RFUs) of individual samples across plates and readers.
Patented PathCheck® Pathlength Measurement Technology: Only Molecular Devices microplate plate readers offer the capability to measure the depth (optical pathlength) of samples in a temperature independent manner using the patented PathCheck® Technology. With SoftMax Pro Software, the PathCheck Technology automatically normalizes the well absorbance.
Comprehensive Reader Validation: Molecular Devices microplate readers have the most complete level of product validation and compliance of any system on the market. A variety of tools are available to users to meet users' diverse validation needs. Molecular Devices provides the complete solution covering the instrument and software.
Automating with Ease: The SpectraMax M3 Microplate Reader has several options when user throughput needs demand walk-away automation. Seamless integration with the StakMax System, Molecular Devices' own integrated microplate stacker designed exclusively for SpectraMax Microplate Readers and AquaMax® Microplate Washers.
For more complex automation needs, SpectraMax M3 Microplate Reader has an automation-compatible reader design for integration into automated platforms. Molecular Devices' microplate readers have been integrated into all major automation platforms.
General Specifications
Dimensions (in.)
8.6 (H) x 22.8 (W) x 15.3 (D)
Dimensions (cm)
22 (H) x 58 (W) x 39 (D)
Weight
36 lbs (16.4 kg)
Power Consumption
< 420 watts
Power Source
100-240 VAC, 3 A, 50/60 Hz
Robotic Compatible
Yes
general photometric performance
Plate Formats
6, 12, 24, 48, 96, 384 wells
Light Source
Xenon Flash Lamp (1 joule/flash)
Detectors
2 photomultiplier tubes
ShakerTime
0 to 999 seconds
Temperature Control
2 °C above ambient to 60 °C
Temperature Uniformity
< 1°C at 37°C set point
Temperature Accuracy
±1°C at 37°C set point
Endpoint Reading
All modes
Kinetic Reading
All modes
Spectral Scanning
All modes
Well Scanning
Abs, FI, TRF, Lum
Typical Read Times (minutes:seconds)††
 
96 wells
384 wells
 
Absorbance
0:18
0:49
 
Fluorescence Intensity
0:17
0:48
 
Fluorescence Polarization
0:42
2:03
 
Time-Resolved Fluorescence
0:17
0:48
 
Luminescence
2:00
7:00
 
absorbance photometric performance
Reading Capabilities
Cuvette or microplate
Wavelength
200-1000 nm
Wavelength Selection
Monochromator, tunable in 1.0 nm increments
Wavelength Bandwidth
< 4.0 nm
Wavelength Accuracy
±2.0 nm
Wavelength Repeatability
±0.2 nm
Photometric Range
0-4.0 OD
Photometric Resolution
0.001 OD
Photometric Accuracy (Microplate)
< ±0.006 OD ±1.0%, 0-2 OD
Photometric Accuracy (Cuvette)
< ±0.005 OD ±1.0%, 0-2 OD
Photometric Precision
< ±0.003 OD ±1.0%, 0-2 OD
Stray Light
< 0.05% @ 230 nm
fluorescence intensity performance
Reading Capabilities
Cuvette or top or bottom of a microplate
Wavelength Range
250-850 nm
Wavelength Selection
Monochromators, tunable in 1.0 nm increments
Bandwidth (Ex, Em)
9 nm, 15 nm
Sensitivity
< 5 pM fluorescein in 96 wells or cuvette,
< 20 pM in 384 wells
luminescence performance
Reading Capabilities
Cuvette or top or bottom of a microplate
Wavelength Selection
All wavelengths or with selected wavelengths
Wavelength Range
250-850 nm
Sensitivity
< 2 fg/well lower detection limit for firefly luciferase in 96- and 384-well top read
Cross-talk
< 0.5% in 96- and 384-well microplates
time-resolved fluorescence performance (M4, M5, M5e only)
Reading Capabilities
Top or bottom of a microplate
Wavelength Range
250-850 nm
Wavelength Selection
Monochromators, tunable in 1.0 nm increments
Bandwidth (Ex, Em)
9 nm, 15 nm
Precision Data Collectionn
1-100 flashes, delay of 0-600 µsec before read, integration time selectable between 50-1500 µsec
Sensitivity
100 fM europium in 96 or 384 wells with top-read
SpectraMax M5e reader only
Certified to Cisbio Bioassays' HTRF assays performance Specifications
fluorescence polarization performance
Wavelength Range
400-750 nm
Wavelength Selection
Monochromators, tunable in 1.0 nm increments
Bandwidth (Ex, Em)
9 nm, 15 nm
Precision
< 5 mP standard deviation at 1 nM fluorescein in 96 and 384 wells
*Specifications subject to change.
*FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
† The PathCheck Sensor is covered under U.S. Patents 5,959,738, 6,188,476, 6,320,662, 6,339,472, 6,404,501, 6,496,260 and 6,995,844. SpectraMax M3, M4, M5, and M5e readers are also covered under U.S. Patents 6,097,025 6,232,608, 6,236,456, 6,313,471 and 6,316,774 6,693,709, and 6,825,921
†† With 3 flashes/well in absorbance and fluorescence modes, and 1 sec./well integration in luminescence.
 
SoftMax Pro Data Acquisition & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software, offers:
  • The most extensive library of "ready-to-run" application protocols to get you started faster
  • Optional tools for regulated labs with SoftMax Pro GxP Compliance Software
  • Advanced calculations including non-linear fitting metrics for in-depth analysis
  • The only Mac- and Windows-native application support for seamless exchange of data files between operating systems
  • Proven integrations with leading automation and LIMS platforms for partnered solutions

产品编号 产品名称 产品简介 产品价格
ML-14478-00 Reader M3多功能酶标仪 Provides three modes of detection in a multi-mode system with the upgrade option to add TRF, FP, and HTRF modes at a later time. Your applications, your modes, your choice. 0¥

相关产品