The Type is a non-contact radar level transmitter for continuous level measurement. It is particularly suitable for use in small vessels that contain beverage liquids under sanitary process conditions. Materials Housing / Cover Seal ring / Ground terminal Wetted parts Process fitting / Antenna / Seal PBT, Stainless steel 316L / PC NBR / Stainless steel 316Ti/316L (1.4571/1.4435) Stainless steel 316L / TFM-PTFE / EPDM Display LCD in full dot matrix (in option) Process fitting Clamp 2”, Varivent® DN25, Flange DN50, DN100 DIN2501 Torque of the flange screws 60 Nm Electrical connection Cable glands M20 x 1.5 Measuring type Distance between process fitting and product surface Min. dielectric figure εr > 1.6 Dead zone 50 mm (from flange) Measuring range 0.05 up to 10 m (Clamp 2”, flange DN50 or Varivent® version) 0.05 up to 20 m (flange DN100) Process temperature with Clamp, flange connection with Varivent® connection -40 up to +150°C (-40 to 302°F) -40 up to +130°C(-40 to 266°F) Vessel pressure1) with Clamp connection with Varivent® connection with flange connection -1 up to 16 bar (-14.51 to 232.16 PSI) (-100 up to 1600 kPa) -1 up to 10 bar (-14.51 to 145.1 PSI) (-100 up to 1000 kPa) or according flange rules