泰亚赛福 —— 世界领先的检测仪器集成供应商
努力为您创造价值
智能 编号 品牌
 您当前的位置:首页 >> 工业检测仪器设备 >> 气体检测仪 >> 复合气体检测仪 >>GasAlertMicro5GasAlertMicro5复合气体检测仪
“复合气体检测仪”专销电话
专销电话
电 话:010-84851836
产品分类
ABCDEFGHIJKLMNOPQRSTUVWXYZ
最近访问过的商品

GasAlertMicro5GasAlertMicro5复合气体检测仪

添加时间:2010-6-4 13:29:24 担当:未知 阅读:

  • 产品名称:GasAlertMicro5GasAlertMicro5复合气体检测仪
  • 定货号:YD-01830-00
  • 推荐:
Five-Gas Detector: H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3 and Combustibles
  • Continuous LCD shows simultaneous gas concentrations for five gases
  • Smaller and over 50% lighter than competitive instruments
  • Water-resistant design with an integral concussionproof enclosure
  • Integral motorized pump option for remote sampling
  • Two power options: AA alkaline or rechargeable hotswappable battery packs
  • Provides 95 dB alarm tone and two bright wideangled alarm bars
  • Equipped with internal vibrating alarm for high noise areas
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Three backlight options: standard梐ctivates in low light (auto), in alarm (auto) and reactivates ondemand; alarm only梐ctivates in alarm conditions and reactivates on-demand; stealth mode?deactivated
  • Four alarm levels: instantaneous Low and High Alarm for all gases;
  • TWA (time-weighted average) and STEL (short-term exposure limit) for toxic gases
  • Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
  • Records TWA, STEL and maximum exposures to gas and displays readings on command
  • User selectable field options include: language selection, confidence beep, span level, set TWA/STEL calculation choice, set calibration due date, passcode protection, latching alarm,
  • "SAFE" display function, stealth mode and selectable ppm resolution for some gases (e.g. SO2 0.1 ppm)
  • Full function self-test of: sensor, battery and circuit integrity; and audible/visual alarms
GasAlertMicro 5 portable gas detector simultaneously monitors and displays up to five potential atmospheric hazards including oxygen, combustible gases and a range of toxic gases. Compact and lightweight, GasAlertMicro 5 adds multigas detection to BW Technologies?water resistant line of detectors. Audible, visual and vibrator alarms activate in the event of a low, high, TWA or STEL alarm condition. An optional motorized pump is available.
Beyond features that come standard with BW portable instruments such as confidence beep, full function self-test, automatic calibration and passcode protection, GasAlertMicro 5 offers an extended selection of user-settable field options now including: stealth mode, backlight options, selectable ppm resolution, STEL / TWA measurement choice, combustible correction factor options, usersettable calibration gas concentrations and multi-language support.
Gas Measuring Range Default Resolution High Resolution TWA STEL LOW HIGH
H2S 0-500 ppm 1.0 ppm 0.1 ppm 10 15 10 15
CO 0-999 ppm 1.0 ppm N/A 35 50 35 200
TwinTox (H2S) 0-500 ppm 1.0 ppm 0.1 ppm 10 15 10 15
TwinTox (CO) 0-500 ppm 1.0 ppm N/A 35 50 35 200
O2 0-30.0% 0.50% N/A N/A N/A 19.5 23.5
SO2 0-150 ppm 1.0 ppm 0.1 ppm 2 5 2 5
PH3 0-5.0 ppm 1.0 ppm 0.1 ppm 0.3 1.0 0.3 1.0
NH3 0-100 ppm 1.0 ppm 0.1 ppm 25 35 25 50
NO2 0-99.9 ppm 1.0 ppm 1.0 ppm 2.0 5.0 2.0 5.0
HCN 0-30.0 ppm 1.0 ppm 0.1 ppm 4.7 10.0 4.7 10.0
Cl2 0-50.0 ppm 1.0 ppm 0.1 ppm 0.5 1.0 0.5 1.0
ClO2 0-1.00 ppm 0.1 ppm 0.01 ppm 0.1 0.3 0.1 0.3
O3 0-1.00 ppm 0.1 ppm 0.01 ppm 0.1 0.1 0.1 0.1
Combustible
Gases
0-100% LEL
0-5.0% v/v
1%
0.1%
N/A N/A N/A 10%
0.5%
20%
1.0%
Auto zero: Yes
Calibration: Automatic
Backlight: Standard Mode: low light (auto); alarm condition (auto); reactivation on demand Alarm Only Mode: alarm condition (auto); reactivation on demand Stealth Mode: backlight inactive; audible and visual alarms silenced
Sensor: Plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL)
User field options: Confidence beep, set STEL period, force calibration on start-up, enable / disable sensor, passcode protection, latching alarms, span level, passed calibration user-lockout option, "SAFE" display function, stealth mode, fast pump, oxygen auto-cal on start-up, alarm only backlight mode, combustible gas measurement (% LEL or % by volume methane), LCD language option, STEL calculation choice, TWA calculation choice, combustible correction factor options, usersettable calibration gas level, high resolution, clock
ALARM INDICATORS: Clearly advises alarm conditions with audible, visual and vibrator alarms
Visual alarms: Two flashing alarm bars visible from all angles. LCD indicates gas present and alarm levels encountered
Audible alarm: Typically 95 dB at 1 ft. / 30 cm variable pulsed audible alarm
Vibrator alarm: Pulses warning in gas alarm conditions or for any status alarms
Status alarms: Low battery, over range, multiple gas / pump and failed or missing sensor
ALARM LEVELS: Instantaneous Low Alarm for all gases; Instantaneous High Alarm for all gases; TWA (time-weighted average) and STEL (short-term exposure limit) for toxics, OL (over alarm) for LEL
LCD: Continuous, alphanumeric gas readout and status display advises:
Gases monitored: H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3, and/or combustibles (0-100% LEL or 0-5.0% methane)
Gas concentration: Simultaneously and continuously displays gas concentration(s) for all sensors (in ppm, % LEL or % v/v)
Peak (MAX)/STEL/TWA ppm: Records exposures and displays on demand
Alarm setpoints: Displayed on activation and on demand
Calibration due date: Days remaining on start-up
Clock: Real-time clock setting displayed on start-up
TESTS:
Full function self-test: Sensor integrity, circuitry, battery and audible/visual alarms on activation
Battery: Continuous
GENERAL SPECIFICATIONS: Rugged, composite material; two-shot molded polymer case with integral anti-shock boot
Operating temperature: -4 to 122OF / -20 to 50OC
Humidity: 0 - 95% RH (non-condensing)
EMI/RFI: Complies with EMC Directive 89/336/EEC
Protection: Highly water resistant and dust proof housing
Battery Options: 23 hours on three AA alkaline cells or 20 hours on rechargeable 揾ot-swappable?battery pack when equipped with oxygen, combustible, TwinTox (H2S/CO) and one additional toxic sensor
Size: 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm
Weight: 13.1 oz. / 370 g
WARRANTY: Full 2-year warranty including all sensors (1 year NH3 sensor)
DATALOGGER OPTIONS: User-downloadable datalogger
Data recorder: All events and occurrences (calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor).
Sampling rate: Factory set at 5-second intervals and user-settable from 1 to 127-second intervals
Storage: 4 months of continuous data at 5 second intervals via memory card; when full, the wrap-around feature replaces oldest data with most recent data


定货信息:
定货号 产品名称 规格配置 价格
YD-01830-00标准配置或电话咨询010-84851836咨询
相关产品