Universal low-frequency (from 20 kHz to 2,5MHz) flaw detector is intended for detection defects (discontinuity and uniformity of materials) in half-finished products and finished articles, for measurement depth and their coordinates position, measurements a thickness, measurement velocity propagation and attenuation of ultrasonic oscillations in composite materials, plastic, concrete and in materials with the big attenuation. A pulse of excitation in the form a radio-frequency pulse with amplitude 200V both regulated frequency and quantity of the periods, and also the high-sensitivity amplifier and possibility to connect the preliminary amplifier, allow to realize the testing with application noncontacts (working through air) transducers. Completely a digital path with processing a radio signal and interface RS232 for personal computer connection, allow to realize various techniques of the testing of products - with processing not only amplitudes of a signal, but also a frequency spectrum or phase components of a signal.
Range: up 160 to 10000 mks
Display: LCD or ELD 110 x 65 mm (240 х 128 pixels) with adjustable contrast and backlight
Amplifier: 20 кHz to 2500 kHz;
Controllable gain: 90 dB with step 0.5, 1, 2 and 6 dB
Probe impulse: a radio impulse amplitude 200 V, with established frequency of filling and number of the periods
Pulse repetition frequency: 10, 25, 100, 200 and 400 Hz
Rectification: positive halfwave, negative halfwave, full-wave, radiosignal (in all ranges)
Reject: linear, up to 0 to 80% screen height |
Monitor gate: two independent monitor gates with individual logic, sound indication
"Freeze" А-signal
Measurement of a thickness on one signal or between two signals
Memory of options: 64 adjustments about possibility of input of the name
Memory of results: 10 files on 100 results of measurement
Communication with PC: interface RS232
Mains power: 4 batteries size "D" or external block
8 hours at the disconnected backlight
Weight: 3 kg with batteries |
Basic Delivery Set
UD2Н-PМ main unit
Power supply 220 V
Probe cable SR50-SR50 2 pieces.
Transducers 60 кHz 2 pieces.
Cable for connection PC
Software support
Documentations
Transport bag
Additional implements
External preliminary amplifier
Batteries "D"
Complete set of batteries the size "D" 9000 mA/hr (4 pieces.)
Universal recharger
Protective bag
Scanner with wheel transducers
Scanner with noncontact transducers
Ultrasonic transducers for diverse application
Technical Characteristics
Calibration Range
min.: 0 - 160 mks
max.: 0 - 10000 mks
Sound velocity range
100 - 4000 m/s
Memory
64 datasets; 10 files on 100 results
Pulse shift
up 0 mks to 7350 mks
Pulse intensity
amplitude 200 V
Amplifier
broadband from 20 to 2500 кHz with filters on 50,
100, 200 and 400 kHz
Controllable gain
90 dB, with step 0.5, 1, 2 or 6 dB
Rectification
positive or negative half wave, complete,
radiofrequency signal
Reject
linear, 0 - 80% screen height
Monitoring gate
two intependent monitor gates with individual logic,
sound indication
Sound path measurement
up to 0 to first signal in zone or between signals in zones
Measurement resolution
1 mks in all range
Display of amplitude
as a procentage of the screen height
Display
LCD with adjustable contrast and backlight,
ELD with adjustable brightness
110 х 65 mm; 240 Х 128 pixels
А-signal
70 mm x 50 mm; 160 x 100 pixels
Interface
RS232
Dimensions transducer
2 SR50
Batteries
4 NiMh size "D"
Operating time from batteries
LCD: 10-14 hours (depending on installations)
ELD: 6-8 hours (depending on installations)
Mains power
via external plug-in power unit 220 V AC
Operating voltage
7.2 - 10 V DC
Power consumption
maximum 5 W, depending on
instrument setting
Operating temperature
LCD: up to -5°C to +50°C
ELD: up to -25°С to +55°С
Dimensions (H x W x D)
220 mm x 120 mm x 150 mm
Weight
2,5 kg with batteries