UDT-40测厚仪
添加时间:2010-3-31 编辑:C055 阅读:次
- 产品名称:UDT-40测厚仪
- 产品定货号:MC-07550-00
Precision, not having analogues of Russia, universal ultrasonic thickness gauge with high reliability of the testing. Presence A –scan excludes such typical mistakes at measurement of thickness as doubling of indications, and B-scan allows observing a structure of a bottom of a product. Thickness gauge realizes various ways of the testing of thickness - measurement of time on transition through "zero", measurement of time between signals, and also frequency and correlation methods of measurement.
Presence of the built in contours of the coordination, adjustable width of a pulse and three electric damping allows to use for measurement any transducers with frequencies from 0,5 up to 15 MHz, both single element and dual type.
Range: 3 to 2975 mm
Display: LCD/ELD 240 х 128
Amplifier: broadband 05-15 MHz
Connection any modern transducers
Controllable gain: 90 dB
Fixing a minimal unit value gauge
A-scan, B-scan(mud line products
"Freeze" А-signal
Correction V-imagery transmission transducers |
Measurement gauge one after one signal and between two signal
Precision indication gauge: 0.001, 0.01 and 0.1
Memory configuration (all parameters device and transducers)
Memory results with possibility watch on-screen
Interface RS232
Mains power: 4 Nimh batteries size "D" or external block
Minimum 8 hours from batteries
Weight 2 kg with batteries |
Basic Delivery Set
UDT-40 thickens gauge electronic module
Electric power supply 220 V
Probe cable SR 50-Lemo 2 pieces
Two transducers
Interface cable RS 233 for connection PC
Software support for PC
Transport bag
Universal Delivery Set
Base delivery set
Protective boot
Module for batteries size "D" 9000
Set batteries NiMh size "D" 9000 mA/hr
Universal charging device
Additional implements
Adapter circuit for connection to USB to port of the PC
Sample of gauge "stupenika"
Ultrasonic transducers for diverse application
Certificated sample of gauge from different fusion
Technical Characteristics
Calibrition range
min.: 0 - 2.9 mm (steel); 0 - 1 mks
max.: 0 - 2975 mm (steel); 0 - 1000 mks
Sound velocity range
1000 - 9999 m/s
Pulse shift
up to -0,5 mks to 996 mks
Damping
50 оhms / 1000 ohms (to 25 ohms in simultaneous mode)
Input impedance
50 оhms / 600 оhms
Sound impulse
quadrangular, amplitude 200V,
with change interval up to 50 to 500 ns,
with step 25 ns
Amplifier
broadband 0.5-15 MHz (-6 dB)
Controllable gain
90 dB, with step 0.5, 1, 2 and 6 dB
Rectification
positive or negative half wave,
complete, radiofrequency signal
Reject
compensate, 0-80% screen height
Inspection zone
two independent monitor gates with individual logic
Alarm
luminous and sonorous
Measurement resolution
to 0 to first signal in zone or between
signals in zones
Dispaly
LCD with regulate contrast and backlight
or with regulate brightness
110х65 mm; 240х128 pixels
Memory
100 datasets for transducers
750 results of measurements with A-scan, parameters of the transducer, date and time
Interface
RS232 or USB
Size transducer
Lemo0 or BNC (optional)
Batteries
4 NiMh size "D"
Operating time
minimum 8 hours
Mains power
external block power 220V AC
Power consumption
maximum 5W, depending
on setting parameters
Operating temperature
up to -20 C to +55 C (ELD)
up to -5 С to +55 С (LCD)
Dimensions (H x W x D)
160 mm x 225 mm x 45 mm
Weight
2 kg with 4 batteries size "С"