| Measuring principle: | Magnetic induction method (F-version); Eddy current method (N-version)  | 
| Measuring range: | 3000PRO:0 - 60.00 mils / 0 - 1500 µm
 | 
| Tolerance: | ± (0.7 µm/0.04 mils + 1% of reading)  | 
| Resolution: | Refer to RESOLUTION TABLE, above  | 
| Display: | 4-digit display (digit height 10 mm/0.4”) and 32 alphanumerical characters; switchable backlight  | 
| Minimum measurement area: | 5 mm x 5mm/0.2” x 0.2”  | 
| Minimum curvature radius: | convex 2mm/0.08”; concave 5mm/0.2”  | 
| Minimum substrate thickness: | 0.2mm/8 mils (for F-versions); 50 µm/2 mils (for N-versions)  | 
| Calibration methods: | - Factory calibration: no calibration required for standard applications- Zeroing (1-point calibration): measurements on small geometries
 - Zeroing and foil calibration (2-point calibration): increased measuring accuracy
 - Two-foil calibration: especially for rough, sand-blasted surfaces
 - CTC: calibration on coated object if zeroing is not possible
 - Zero offset: addition/subtraction of a constant value to/from the reading
 | 
| Limit values: | Selectable; optical and acoustic signal if limit value is exceeded  | 
| Scan mode: | For continuous measurements; for the quick recognition of coating thickness variations;with permanent display of minimum and maximum reading
 | 
| Statistics: | Single-value statistics: n, avarage x, s, kvar, min, max, cp, cpk from max. 10,000 readingsBlock-value statistics: n, avarage x , avarage s, avarage kvar , min, max, cp, cpk; block size 3 to 100 readings
 | 
| Data memory: | 10,000 readings in max. 500 selectable files; alphanumerical file names; stored readings and statistical values individually recallable  | 
| Interfaces: | Infrared and serial RS232 interface  | 
| Language: | Operator prompting and documentation in German, English, French (optional other languages)  | 
| Operating temperature: | 0 °C to 50 °C/32 °F to 122 °F (storage temperature - 20 °C to +60 °C/-4 °F to 140 °F)  | 
| Surface temperature: | 5° F - 140° F / -15° C - 60° C (standard)5° - 302° F / 15° - 150° C (w/optional footer)
 | 
| Power supply: | 2 x round cell (AA) 1.5 V up to 60 hours of operating time  | 
| Housing/keypad: | Protection class IP52 (protection against dust and dripping water)  | 
| Dimensions: | Gauge: 140 mm x 62 mm x 30mm/5.6” x 2.5” x 1.2” (HxWxD)Probe: dia. 14 mm x 83mm/dia. 0.56” x 3.3”
 | 
| Weight: | approx. 200 g/7 oz (gauge including batteries and probe)  | 
| Standards: | DIN EN ISO, ASTM, BS  | 
| Warranty | 1 Year  | 
| Calibration Certificate | Included  |