The fitting S030 has a built-in paddlewheel to measure the flowrate. When liquid flows through the pipe, the paddle-wheel is set in rotation producing pulses which frequency is proportional to the flowrate. This leads to a very leak-proof construction, called the ”INLINE Quarterturn” technology. The paddle-wheel rotation is detected contactless through the fitting wall. The sensor unit can be snapped-on or removed without opening the pipe or interrupting the process.
General data
Pipe diameter DN 06 up to DN 65
Measurement range from 0.5 up to 1200 l/min
Flow velocity 0.3 up to 10 m/s (see flow diagram)
Accuracy1) Individual works calibration (Teach-In, via a remote transmitter) or standard mean K-factor, see accuracy chart on next page.
Linearity1) ≤ ±0.5% of F.S.* (at 10 m/s)
Repeatability ≤ 0.4% of Reading*
Fitting port connection
Internal or external thread, weld ends, Clamp or flange
True union, spigot or external thread
Shaft and bearing
FKM or EPDM (depending on version, see ordering chart)
Stainless steel (316L -1.4435), brass (CuZn39Pb2),
PVC, PP, PVDF
Stainless steel (316L -1.4435)
PVDF (PP on request or stainless steel, see data sheet 8030HT)
On/Off flow
sensor/switch
• DN 06 to DN 65
• Closed pipe system, i.e. sensor inside fitting
• Quarter-turn technology
• Electronics available for
- Indication, Monitoring, Transmitting
- On/Off control, Batch control
Medium data
Fluid temperature 0 up to 50°C (32 to 122°F) for fitting in PVC
0 up to 80°C (32 to 176°F) for fitting in PP
-15 up to 100°C (5 to 212°F) for fitting in stainless steel,
brass or PVDF