产品描述:
The RADOS RAD-60 Personal Alarm Dosimeter is a precise and reliable instrument for ensuring the personal safety of the user. Ideally, the RAD-60 is used in everyday radiation monitoring, in stand-alone conditions. If your needs grow for a more sophisticated system, the versatile RAD-60 can also be integrated into an Access Control System. The RAD-60 can be switched into System Mode, for the purpose of tracking Personnel Dose records and generating compliance reports.
The design includes state-of-the-art technology with built in memory for retrieving dose, even during power-down. It eliminates outside interference from shock and RF. The RAD-60 is easily programmed by the user, has a digital display, and operates with a single AAA alkaline battery.
With the push of a button, you can turn the unit on/off, change the digital display to read dose or dose rate, select from several dose and dose rate alarm levels, turn the chirp functionon/off, reset the integrated dose, and perform battery tests. The large digital display gives instant dose or dose rate readings and the audible alarm is loud (>85dba)
Specifications
Detector Energy compensated Si-Diode Button Functions Front panel button has the following functions: • change display priority (dose/dose rate) • switch ON/OFF • chirp ON/OFF • reset integrated dose • change alarm thresholds • activate battery test Measurement Range Dose: 1 uSv - 9.99 Sv or 0.1 mrem - 999 rem Energy Response Hp(10), 60 keV - 3 MeV, better than + or - 25%, up to 6 MeV, better than + or - 35% Dose Rate 5 uSv/h - 3 Sv/h or 0.5 mrem/h - 300 rem/h Dose Rate Linearity Better than + or - 15% up to 3 Sv/h (300 rem/h) Calibration Better than + or -5% (Cs-137, 662 keV at 2 mSv/h), Hp(10) Audible Alarms Seven separate alarms, sound level typically better than 85 dBA at 30 cm • integrated dose • dose rate • dose overflow • dose rate overflow at 3 Sv/h or 300 rem/h • low battery 1 and 2 • defect |
Alarm Thresholds
Six preset values each for integrated dose and dose rate-push button selection
Connectors
Infrared communication via bottom of the dosimeter
Power Requirements
One triple A alkaline cell, typical life is 1800 hours in background (dose mode)
Temperature Range
-20 - + 50° C operational, humidity up to 90% RH, non-condensed -20 - + 70° C storing
Weight
80 g (including battery)
Size
78 x 67 x 22 mm
购买流程:
①购买产品:点击“生成订单”→填写产品数量、联系方式并提交→会员顾问订单处理→合同签订。
②咨询产品:请联系会员顾问或致电会员客服电话。
③如果您还不是我们的会员,请先注册。
④最小起订数量:1
注意:本产品唯一个人现金委托收款人,如汇入其它个人账户本公司不承担任何责任
维护担当:
上线时间:
投诉电话:13801126385 13911302309
泰亚赛福作为众多知名品牌的合作伙伴,优惠的价格+完善的售后服务体系向您提供产品。font>