Features & Benefits
Detects all CFC, HFC, and HCFC Refrigerants
Manual or automatic, auto zero balance control
Pass / Fail test mode
Unique sensor calibration system
CE Mark
Pinpoints both small and large leaks
Specifications
Detects: All CFC, HFC, and HCFC Refrigerants
Sensing Element: Positive Ion Emission Heated Diode
Sensitivity: Moving probe test per SAE Std. J1627
Alarm Sensitivity:
R-134a
Moving Probe
Small - 0.5 oz/year
Medium - 1.0 oz/year
Large - 5.0 oz/year
Stationary Probe
Small - 0.1 oz/year
Medium - 0.5 oz/year
Large - 2.0 oz/year
R-12
Small - 0.1 oz/year
Medium - 0.5 oz/year
Large - 3.0 oz/year
Warm-Up Time: Approx. 2 minutes
Accuracy: Exceeds SAE J1627
Probe Length: 4.5 feet
Dimensions: 5.5" x 10.5" x 8.5"
Weight: Approx. 5 lbs
Agency Listings: UL file SA9717, SAE J1627, CE-Mark
Power:
12 VDC - internal rechargeable, sealed lead acid battery
12 VDC - external battery using battery clamp/cigarette lighter plug
120 VAC - wall adapter to charge battery only
120 VAC - optional wall adapter to charge-and-run unit continuously
Internal AC voltage adapters available
Leak Alarm: Audible alarm and visible neon lamp
Response Time: Approx. 1 sec.