The AGA5000
has the following features:
• Measures:
• Carbon Monoxide (CO)
• Hydrocarbons (HC)
• Carbon Dioxide (CO2)
• Oxygen (O2)
• Nitric Oxide (NOX)
• Measures five gases individually (actual, not calculated)
• Infrared link to optional portable printer
• Programmed to evaluate gasoline, LPG and CNG fuels
• Programmable four or eight line backlit display
• Separate pump switch (Run pump only during testing)
• Measurements are shown in real time
• Self-powered, the only connection to the vehicle is the tailpipe hose
• Integral flow checking provides warning of probe blockages
• The calibration procedure uses standard automotive test gases
• Includes: Protective rubber boot, Water trap and filter, Carrying case,
Battery charger, exhaust probe and five extra filters
• One year limited warranty
Gases Resolution Accuracy Range
CO 0.01% ±5% of reading 0-5%
±0.5% volume Over-range 20%
O2 0.01% ±5% of reading 0-21%
±0.1% volume Over-range 25%
HC 1 ppm ±5% of reading 0-2000 ppm
±12 ppm volume Over-range 10,000 ppm
NOX 1 ppm ±5% pf reading 0-5000 ppm
±40 ppm volume Over-range 5,000 ppm
CO2 0.1% ±5% of reading 0-16%
±0.5% volume Over-range 20%
Lambda 0.001 - 0.8-1.2
AFR 00.01 - 11.76-17.64
Sensor response time 15 seconds
Pre-programmed fuels Gasoline, LPG and CNG
Ambient operating range +41°F to 104°F / 10% to 90% RH non condensing
Hose length 12’
Battery charger Input: 110V AC
Output: 10V AC off load
Analyzer battery run time > 4 hours from full charge with pump running