Gas Range Alarm
Combustible 0-100%LEL 10%LEL
Oxygen 0-25% 19.5/23.5%
Hydrogen Sulfide 0-50ppm 10ppm
Carbon Monoxide 0-500ppm 35ppm
Sulfur Dioxide 0-10ppm 2ppm
Chlorine 0-5ppm 0.5ppm
Nitrogen Dioxide 0-10ppm 3ppm
Nitric Oxide 0-100ppm 25ppm
Ammonia 0-50ppm 25 ppm
Ozone 0-1ppm 0.1 ppm
Hydrogen 0-1000ppm N/A
Hydrogen Cyanide 0-25ppm 5 ppm
Hydrogen Chloride 0-10ppm 1 ppm
Hydrogen Fluoride 0-10ppm 1 ppm
Phosphine 0-2ppm 0.2 ppm
Ethylene Oxide 0-10ppm 5ppm
Other ranges and alarm levels are available on request. Each gas channel canhave two instantaneous alarm levels set. Toxic channels also have Time
Weighted Average alarms.
Combustible gas calibration is available for methane, propane, butane,pentane and ethylene as standard.
Typical response times Combustible 20 s, Toxic gas 20 s, Oxygen 10s
Audible Alarms 90 dBA at 1ft
Multiple alarm sounds allow selection of distinctive tones for different alarm levels
Visible Alarms Dual colour red/blue flashing LED pair in gas hazard
Vibrating alarm Internal vibrating alarm
Display Graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), pump operation, healthy operation or fault warning. Start up indication when calibration is due within 30 days, calibration overdue, or service required.