Features
RS-485 MODBUS Serial Output 
4-20mA Analog Output 
Field Programmable Alarm Relays 
14-28 VDC Operation 
Automated Non-Intrusive Calibration 
Liquid Crystal display with back light 
Description
featuresUltra 1000 series is a microprocessor based addressable sensor for detection of Hydrogen Sulfide in ambient air. The self- contained sensor  user friendly interface and menu driven calibration procedure and configuration. 
The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a transmitter board assembly. All of the sensor electronics are enclosed in an explosion proof instrument box. The unit’s modular design allows easy maintenance, troubleshooting and high reliability. 
The unit provides a 4-20mA signal proportional to 0 to 100% of the detection range. In addition the sensor may be addressed via MODBUS RTU interface. The MODBUS output provides sensor status, alarm & fault conditions. Alarm levels can be programmed via MODBUS RTU or via magnetic switch on the face of the transmitter board assembly. 
Ultra 1000 can be calibrated in less than 2 ½ minutes. The calibration and the set-up parameters are retained in a non-volatile memory. 
Specifications
Sensor Type 
Electrochemical (Also available in Solid State MOS) 
Measuring Range 
0 – 100 ppm (parts per million) 
( 500 ppm extended range also available) 
Repeatability 
± 2 % Full scale 
Zero Drift 
< 5% per year 
Response Time 
T90 < 30 seconds with 100% FS gas applied 
Classification 
Class I, division 1, Groups B, C & D 
Operating Temperature 
-4°F to +122°F (-20°C to +50°C) 
Operating Humidity 
15% to 90% RH, non-condensing 
Display 
2 lines by 8 Character LC Display with back light 
Mechanical Specifications 
Length: 7 inches (178 mm) 
Width: 5 inches (127 mm) 
Height: 4.5 inches (114 mm) 
Status Indicators 
LC Display for gas concentration, Alarm relay status, calibration mode and sensor fault status. 
Input Power 
14-28 VDC. 24 VDC nominal 
Power Consumption 
60mA @ 24 VDC Typical 
Alarm Relays 
Fully programmable. 0 to Full scale range of the sensor. Latching or Non-Latching. 
Relay Ratings 
SPDT Form “C” type Relay contacts 
5 Amps @ 250 VAC or 30 VDC 
Analog Output 
Linear 4-20mA (300 Ohms max. load) 
2.0 mA - Calibration mode 
< 1.0 mA - Sensor malfunction 
Interface 
RS-485 MODBUS RTU (2 wire) at 9600 Baud rate 
Cable Entry Hub 
¾” NPT Female 
Features
RS-485 MODBUS Serial Output 
4-20mA Analog Output 
Field Programmable Alarm Relays 
14-28 VDC Operation 
Automated Non-Intrusive Calibration 
Liquid Crystal display with back light 
Description
Ultra 1000 series is a microprocessor based addressable sensor for detection of Hydrogen Sulfide in ambient air. The self- contained sensor features user friendly interface and menu driven calibration procedure and configuration. 
The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a transmitter board assembly. All of the sensor electronics are enclosed in an explosion proof instrument box. The unit’s modular design allows easy maintenance, troubleshooting and high reliability. 
The unit provides a 4-20mA signal proportional to 0 to 100% of the detection range. In addition the sensor may be addressed via MODBUS RTU interface. The MODBUS output provides sensor status, alarm & fault conditions. Alarm levels can be programmed via MODBUS RTU or via magnetic switch on the face of the transmitter board assembly. 
Ultra 1000 can be calibrated in less than 2 ½ minutes. The calibration and the set-up parameters are retained in a non-volatile memory. 
Specifications
Sensor Type 
Electrochemical (Also available in Solid State MOS) 
Measuring Range 
0 – 100 ppm (parts per million) 
( 500 ppm extended range also available) 
Repeatability 
± 2 % Full scale 
Zero Drift 
< 5% per year 
Response Time 
T90 < 30 seconds with 100% FS gas applied 
Classification 
Class I, division 1, Groups B, C & D 
Operating Temperature 
-4°F to +122°F (-20°C to +50°C) 
Operating Humidity 
15% to 90% RH, non-condensing 
Display 
2 lines by 8 Character LC Display with back light 
Mechanical Specifications 
Length: 7 inches (178 mm) 
Width: 5 inches (127 mm) 
Height: 4.5 inches (114 mm) 
Status Indicators 
LC Display for gas concentration, Alarm relay status, calibration mode and sensor fault status. 
Input Power 
14-28 VDC. 24 VDC nominal 
Power Consumption 
60mA @ 24 VDC Typical 
Alarm Relays 
Fully programmable. 0 to Full scale range of the sensor. Latching or Non-Latching. 
Relay Ratings 
SPDT Form “C” type Relay contacts 
5 Amps @ 250 VAC or 30 VDC 
Analog Output 
Linear 4-20mA (300 Ohms max. load) 
2.0 mA - Calibration mode 
< 1.0 mA - Sensor malfunction 
Interface 
RS-485 MODBUS RTU (2 wire) at 9600 Baud rate 
Cable Entry Hub 
¾” NPT Female