The Series 9502 Carbon Dioxide Monitor features a next generation infrared sensor that redefines the science of infrared gas sensing. The compact and easy to use Series 9502 CO2 Monitor is suitable for applications in HVAC Demand Control Ventilation, Environmental Chambers, Indoor Air Quality, Greenhouse Monitoring, and many other commercial and industrial applications.
Features |
Benefits |
Non-dispersive IR Sensor |
Exceptional Reliability |
Factory Calibrated |
Ensures Accurate Readings from the Start |
Sturdy ABS Case |
Handles the Rigors of Industrial Applications |
Isolated Power Supply |
Eliminates Ground Loop Problems |
Large LCD Display |
Easy to Read from Distance as well as Angles |
Adjustable Alarm Relay |
Alert Personnel of Unacceptable CO2 Levels |
System Description
The Series 9502 CO2 Monitor features a next generation infrared sensor that redefines the science of infrared gas sensing. The compact and easy to use Series 9502 CO2 Monitor is suitable for applications in HVAC Demand Control Ventilation, Environmental Chambers, Indoor Air Quality, Greenhouse Monitoring, and many other commercial and industrial applications.
The non-dispersive infrared (NDIR) sensor is the focal point of the Series 9502 CO2 Monitor. Unlike electrochemical carbon dioxide sensors, non-dispersive infrared gas sensors do not chemically react with the gas being sampled. The ability of certain gases to absorb infrared radiation has been successfully utilized in developing various gas sensing instruments. A key advantage factor over traditional IR sensors is the ease in which the Series 9502 can be field calibrated. Its superior design makes field calibration fast and easy. And, because of the high reliability components used in the Series 9502 Carbon Dioxide Monitor, calibration intervals are much longer (years rather than months) than rival devices.
The Series 9502 CO2 Monitor comes equipped with an easy-to-see 0.35” high liquid crystal display, single adjustable alarm relay, and a 4-20 mADC linear output that can be used with a recorder, datalogger, etc. In addition to the 4- 20 mADC output, the Series 9502 CO2 Monitor has a 0-10 VDC analog output also. Both analog outputs can be scaled by the user over any low and high values as long as they don’t exceed the range of the monitor.
Back To Top
Specifications
Measurement Range: 0-5,000 Parts Per Million (PPM)
Measurment Error: ± 5% of reading at standard or ± 75 ppm whichever is greater stated at a temperature and pressure (250°C and 760 mm Hg)
Response Time: < 60 seconds to 90% of step change
Sensor Type: NDIR-Non Dispersive Infrared
Gas Sampling Method: Diffusion
Pressure Effect: 0.19% of reading per mm Hg
Repeatability: ± 20 ppm
Warm-up: <180 seconds
Operating Temperature Range: 0° to 50° C
Humidity Range: 0-95%, non-condensing (when in operation)
Calibration Interval: 3 years recommended with no initial customer calibration required
Power Source: 18-30 VDC, 20-28 VRMS AC. Power consumption < 2 watts @ 24 VDC
Analog Outputs: A linearized 0-10 VDC or 4- 20 mADC (RL < 500 ohms), user selectable
(analog outputs can be adjusted by user)
Relay Output: Adjustable single trip point. Rated 2A@ 24 VDC
Digital Display: 4 digit 0.35” liquid crystal display (LCD)
Warranty: Two years (expected operating life expectancy > 10 years)
Enclosure Material: ABS
Dimensions: 5.2” H x 3.2” W x1.4” D