首页 > 气体检测 >  气体检测仪 > 单一气体检测仪 > 氧气检测仪(O2) > series3510氧气分析仪
series3510氧气分析仪
series3510氧气分析仪
订货号: MM-40386-00
产地: 美国
品牌:
开发编号: N
市场价:
*此产品根据配置不同价格不同
*此价格为参考价格,具体价格以订单合同为准
    我在现场:
    产品视频:
  • 产品描述
  • 技术参数
  • 技术文档
  • 相关产品
  • 明细价格
  • 购买流程
产品描述:

Features
Benefits
Wide Number of Ranges
Measure from <1ppm to 10,000 ppm Oxygen
Exceptional Speed of Response
Responds Instantaneously to Changes in Oxygen
Rugged and Versatile Construction
NEMA 4 Housing Withstands Harsh Environments
Economically Priced
Save Thousands of Dollars vs Other Methods
Patented Electrochemical Sensor
Offers Exceptional Accuracy and Stability
Sealed Sensor
Eliminates Having to Handle Liquid Caustic
System Description
The Series 3500 Trace Oxygen Transmitter features an advanced electrochemical oxygen sensor that provides exceptional performance, accuracy, and stability. In addition, the enhanced mechanical design of the sensor ensures longer life, and virtually eliminates leakage of caustic electrolyte, a nagging problem associated with sensors that require periodic electrolyte maintenance. And, because the sensor is sealed, it is not position sensitive. In addition, Alpha Omega Instruments oxygen sensors are temperature compensated to provide optimum performance over a wide range of operating conditions.
The Series 3510 Trace Oxygen Transmitter is both dustproof and waterproof, and is rated for NEMA 4 (IP66) service. The instrument is powered from 115VAC, 60Hz, and provides a 4-20 mADC output that can be transmitted to a datalogger, recorder, PLC, DCS, etc. Internal shielding of the electronics offers excellent protection from EMI/RFI noise. Accessories for the Series 3510 Trace Oxygen Transmitter include a pressure regulator, in-line sample filter, and sample pump (shown in upper photo).
The Series 3510 Trace Oxygen Transmitter features an advanced electrochemical oxygen sensor that provides exceptional performance, accuracy, and stability. In addition, the enhanced mechanical design of the sensor ensures longer life, and virtually eliminates leakage of caustic electrolyte, a nagging (and expensive) problem associated with sensors that require periodic electrolyte maintenance. And, because the sensor is sealed, it is not position sensitive. In addition, the Series 3510 Trace Oxygen Transmitter does not require an adjustment in readings when the gas composition changes as do some other analyzers. The output from the sensor is temperature corrected to provide optimum performance over a wide range of operating conditions.
Back To Top
Specifications
Measurement Ranges (parts per million): 0-10, 0-50, 0-100, 0-500, 0-1,000, 0-5,000 and 0-10,000 (special ranges available upon request)
Accuracy: ±1% of full scale
Linearity: ±1% of full scale
Response Time: 90% of full scale in less than 10 seconds typical
Sensor Type: Patented Electrochemical Sensor
Temperature Compensation: Standard
Operating Temperature Range: 40° - 100°F (5° to 38°C)
Sample Gas Pressure Limits: 0.1 to 1.0 psig (1.04 kg/cm² to 1.10 kg/cm²)
Sample Flow Rate: 1.0 to 2.0 SCFH (0.5 to 1.0 liters/min.)
Electrical Input/Output: 14-32 VDC @ 4-20 mADC
 


品牌简介

Alpha Omega Instruments仪器公司致力于用更好的产品满足于客户。随着当今世界经济的发展,为在全球基础上开展业务提供了很多机会和挑战。Alpha Omega Instruments仪器公司对…Alpha Omega Instruments仪器公司致力于用更好的产品满足于客户。随着当今世界经济的发展,为在全球基础上开展业务提供了很多机会和挑战。Alpha Omega Instruments仪器公司对产品的广度,以及应用经验的深度,做出了正确的建议,第一时间得到解决。Alpha Omega Instruments仪器公司有两个主要的企业集团。其光电集团制造的热电冷却器控制器与全球定位卫星,高分辨率光谱仪,激光表征设备,惯性制导系统,医疗诊断设备等被广泛应用。另一个为流程分析器集团,生产冷镜露点湿度计,跟踪仪,氧气分析仪,变送器,环境空气中的氧监视器,二氧化碳分析仪等。

您最近浏览的商品