Measured Parameters |
L (Inductance), C (Capacitance), R ( Resistance), Z (Impedance), X (Reactance), Q (Quality factor), D (Dissipation factor), Θ (Phase angle in degrees or Radians); The following Parameters are monitored only, no values for the parameters may be entered: G (Conductance) B (Susceptance), Y (Admittance), Vac ( Test signal voltage) and Iac (test signal current)) |
|
|
Measured Parameter |
R + Q, R + X |
Measurement |
RX: 0.0001Ω to 9999.9MΩ Q: 0.0001 to 9999.9 |
|
|
Measured Parameter |
Z+Θ ( Phase angle in Degrees or radians) |
Measurement range |
Z: 0.0001Ω to 9999.9MΩ Θ? : -179.99? to 179.99? Θr: -3.1416 to 3.1416 |
|
|
Measured parameter |
L + Q, L + R |
Measurement range |
L: 0.0001nH to 9999.9H Q: 0.0001 to 9999.9 R: 0.0001Ω to 9999.9MΩ |
|
|
Measured parmeter |
C+R, C+D |
Measurement range |
C: 0.0001pF to 9999.9mF D: 0.0001 to 9999.9 R: 0.0001Ω to 9999.9MΩ |
|
G,B and Y ( Displayed only) |
|
Measurement range |
G, B, Y: 0.00001nS to 999.999S |
|
|
Test Voltages |
0.1V, 0.3V, 1.0V |
Test Voltage Accuracy |
±(10% + 10mV) |
Test Frequencies |
50Hz, 60Hz, 100Hz, 120Hz, 1KHz, 10KHz, 20KHz, 50KHz, 100KHz |
Test Frequency Accuracy |
± 0.02% |
Measurement Rates |
Slow: 1.5 Measurements/Sec Medium1: 5 Measments/Sec Medium2: 10 Measurements/Sec Fast: 30 Measurements/Sec |
|
|
Types |
Auto, Hold and Nominal Nominal ranging the Z9500 selects the best range according to the nominal value being measured |
Measurement Circuit configurations |
Series and Parallel |
Output Impedances |
30Ω, 50Ω, 100Ω |
|
|
Modes |
Internal, External, Manual, Bus |
|
|
Display Type |
3.5" TFT Multi line Color LCD with Back light |
Displayed Values: |
5 Digit multi line display of L,C,R or Z measurements and Q,D or Θ Mon1 and Mon2: Displays Y, B, G, Iac, Vac, L, R. Z,D, Θ or Q (Mon1 and Mon2 are displayed simultaneously on the LCD as separate lines) |
Parameters Displayed |
Measrements are displayed as: Absolute value, ? absolute , ? % |
|
|
Basic Accuracy |
± 0.05% (see manual for accuracy conditions) |
Input Compensation |
Short and open circuit cand Load ompensation |
|
Component sorting (comparator function) |
|
Sorting types |
Binning: Components are sorted in to 5 Bins , Bins 1-3, Aux and out of tolerance according to preset tolerances and Hi/Lo limit testing |
|
|
Interfaces |
RS232, Handler and USB (RS232 to USB convertor) RS232 commands are SCPI compliant Optional front panel USB host port. |
Storage |
10 component setups may be stored and recalled from internal memory. Additiional setups and data may be stored in a flash RAM connected to the optional Front panel USB host port |
|
|
Power requirements |
120V AC 50/60Hz.. 220V AC operation upon request at time of purchase |
Power consumption |
Approximately 25 watts |
Operating temperature |
32°F to 155°F (0°C to 55°C) |
Calibration temperature |
73°F ± 9°F (23°C ± 5°) |
Operating Humidity |
15% to 85% at a wet bulb temperature of =104°F (40°C) |
Dimensions |
10.4" (W) x 4.21" (H) x 13.8" (D) 264mm x 107mm x 350mm |
Weight |
5.84lbs (2.64 Kg) |
Accessories |
Operator's manual, Test leads with Kelvin clips, Radial lead test adapter, Shorting bar AC line cord, RS232 cable, USB cable, USB to RS232 adapter and USB driver software. |
|