您好,欢迎来到泰亚赛福!收藏泰亚赛福
订货号: | MM-29868-00 |
产地: | 美国 |
品牌: | |
开发编号: | N |
市场价: | ¥ |
*此产品根据配置不同价格不同 |
*此价格为参考价格,具体价格以订单合同为准 |
Size |
48.9 cm wide x 50.8 cm deep x 33.7 cm high
19-1/4 in wide x 20 in deep x 13-1/4 in high |
Weight |
21.6 kg / 48 lb |
Power Requirements |
115 V ac, 60 Hz, 1 A or 220 V ac, 50-60 Hz, 0.5 A |
Resistance Meas Channels |
Eight |
Measurement Ranges | |
*Resistance |
0 to 4000 milliohms |
*Resistance test current |
10 or 100 milliamperes in accordance with MIL-S-8805 (selectable) |
*Force |
0 to 3.6 kilograms standard |
Total Displacement |
0.246 inch (button tip to bottomout) standard (programmable to 2.46 inches) |
Test time |
4 to 10 seconds standard (programmable) |
Sensitivity | |
*Resistance |
1 milliohm |
*Force |
1 gram |
**Displacement |
0.0001 inch standard |
Test time |
4 to 10 seconds standard (programmable) |
Absolute Accuracy |
Maximum |
Typical |
Resistance |
±0.25% of full scale |
±0.1% of full scale |
Force |
±0.25% of full scale |
±0.2% of full scale |
**Displacement |
±0.0003 inch |
±0.0001 inch |
Repeatability | ||
Resistance |
±0.1% of full scale |
±0.05% of full scale |
Force |
±0.1% of full scale |
±0.05% of full scale |
**Displacement |
±0.0003 inch |
±0.0001 inch |
Parameter |
Description |
Actuation Window(in/out) |
The distance from the first switch contact change to the point where all contacts have transferred completely (no more bounce). |
Blackout |
The dead band that exists during contact set transition (differential measurement). |
Contact Resistance(max, min & avg) |
The resistance measured from the first contact change plus blackout to the point where bottomout occurs for inward motion, or to the point where button-free position occurs for outward motion. |
Free Position |
The location of the top of the switch button (actuator) with no force applied against it. The free position is measured with respect to a predetermined reference point. |
Movement Differential |
The difference in distance between the operating point and the reset point (differential measurement). |
Operating Force |
The maximum force measured during pretravel. |
Operating Point(or position) |
The point where all contacts have transferred at least once (ignores bounce). Measured with respect to a predetermined reference point. |
Overtravel |
The distance from the operating point to the point where bottomout occurs (differential measurement). |
Pretravel |
The distance measured from the button-free (rest) position to the operating point (differential measurement). |
Reset Force |
The minimum force measured from bottomout to the reset point. |
Reset Point |
The point where all contacts have transferred back, at least once, to their original (releasing position) positions (ignores bounce). Measured with respect to a predetermined reference point. |
Reset Travel |
The distance from the reset point to free position (differential measurement). |
Simultaneity> |
The distance from a reference contact set or first contact, to the actuation of another contact set. Measured when more than one contact set is being tested. |
定货号 | 产品名称 | 规格配置 / 简介 | 市场价/(会员价) |
---|---|---|---|
MM-29868-00 | 951自动开关试验站 | /() |