The Type 8186 is a level transmitter with rodprobe, designed for continuous level measurement.The unit is suitable for liquids, but also forsolids, for industrial use in all areas of processtechnology. It can be used in corrosive liquids.Even process conditions such as strong steamgeneration, density fluctuations or changes of thedielectric constant do not influence the accuracyof the measurement.Buildup or condensation on the probe or vesselwall do not influence the measuring result。
Materials
Housing / Cover
Seal ring / Ground terminal
Inner conductor , Rod-ø 10 mm
Wetted parts
Process fitting / process seal
Rod-ø 10 mm
PBT, Stainless steel 316L / PC
NBR / Stainless steel 316L
Stainless steel 316L (1.4435)
PFA and TFM PTFE / FKM
PFA and TFM PTFE
Display LCD in full dot matrix
Weight
Housing890 g
Rod-ø 10 mm
approx. 350 g/m
Process fitting Clamp 2” or DIN 11851 DN 50
Length 0.3 ... 4 m - Lateral load: 4 Nm
Electrical connections Cable gland M20 x 1.5
Measuring type Level of liquids and solids
Min. dielectric figure år > 1.6
Dead zone From top of probe: 80 mm - from bottom of probe: 0 mm
Measuring range 0.08 ... 4 m (See measuring range diagram, on next page)
Process temperature -40 up to 150°C (-40 to 302 °F) (flange temperature)
Process pressure -1 to 16 bar (-14.51 to 232.16 PSI) (-100...1600 kPa) (depends on the process fitting)
Temperature drift 0.06%/10K (Relating to the max. measuring range)