New digital ultrasonic flaw detector, created for replacement of out-of-date analog devices UD2-12. Keeping opportunities of analog processing and having completely a digital path the device allows carrying out all functions ultrasonic flaw detector UD2V-P45/46 except for preservation of results of the testing and communication with the personal computer. Ultrasonic flaw detector can be modernized in the further up to version UD2V-P46.
It is intended for detection of defects (discontinuity and uniformity of materials) in semi-finished items, finished articles and welded joints, for measurement of depth and their coordinates, measurements of thickness, measurement of velocity of propagation and attenuation of ultrasonic oscillations in a material.
Has the high-contrast liquid crystal display, it is simple and convenient in circulation.
Range: 3 to 2975 mm
Display: LCD 110 mm x 65 mm (240 x 128 pixels) with switchable backlight
Controllable gain: 110 dB
TGC/DAC function
Alarms for gates
Pulse echo and dual operation
PRF: up to 800 Hz to 40Hz
Rectification: RF (in all ranges), full-wave, positive and negative half wave
Reject: 0 to 80% screen height |
Two independent monitor gates with individual logic
A-scan image freeze and zoom
Trigonometric functions
Digital measurement resolution: 0.001 mm up to 10 mm steel
Memory: 12 datasets with A-scan and no measurements results
Mains power: 4 NiMh batteries size "D" or via external plug in power unit
16 hours operating with backlight
Weight: 2.5 kg with batteries |
Basic Delivery Set
UD2V-P45.Lite main unit
AC-DC power supply 220V
Probe cable CR 50-Lemo 2 pieces
Two transducers
Batteries set unit NiMh size "D" 9000 mA/hr
Documentations
Transport bag
Additional implements
Ultrasonic transducers for differently application
Standard samples
Тechnical Characteristics
Calibration range
min.: 0 - 2.9 mm (steel); 0 - 1 mks
max.: 0 - 2975 mm (steel); 0 - 1000 mks
Sound velocity range:
1000 - 9999 m/s
Pulse shift
up to -0,5 mks to 996 mks
Probe delay:
0 - 100 mks
Damping
50 ohms / 1000 ohms
Resiver
50 ohms / 600 ohms
Pulse intensity
quadrangular, amplitude 200V,
with change interval up to 50 to 500 ns,
with step 25 ns
Pulse repetition frequency
up to 800 Hz or 40 Hz
Amplifier
broadband 1-10 MHz (-3 dB)
Controllable gain
110 dB, with step 0.5, 1, 2 or 6 dB
TGC/DAC
curve recording with maximum of 10 reference echoes.
Rectification
RF (in all ranges), full-wave,
positive and negative half wave
Reject
linear, 0-80% screen height
Monitor gate
two independent monitor gates with individual logic, variable in steps of 1%
Alarm
sonorous and luminous
Sound path measurement
digital display of sound path between zero and the first echo signal
in the gate or between two echoes in the gates, measurement at echo flank
or peak with trigonometric flaw location.
Measurement resolution
3.125, 6.25, 12.5 or 25 ns depending on PRF
Display of amplitude
as a percentage of the screen height
in dB to reference test echo
in dB reference to DAC curve.
Display
LCD with switchable backlight and
(110 mm x 65 mm; 240 x 128 pixels)
А-signal
73 mm x 50 mm; 160 x 100 pixels
Memory
12 datasets with А-signal
Interface with PC
no
Dimensions transducers
2 SR50
Batteries
4 NiMh size "C" or "D"
Operating time
16 hours from batteries 9 А/hr "D"
with backlight
Power supply
external block 220 V AC
Operating voltage
4 - 10 V DC
Power consumption
maximum 5 W, depending on instrument setting
Operating temperature
up to +5 C to +55 C
Dimensions (H x W x D)
160 mm x 225 mm x 45 mm
Weight
2,5 kg with batteries