简易PCR仪 | 梯度PCR仪 | 荧光实时定量PCR仪
食品快速检测仪 | 食品微生物快速检测仪 | 食品安全快速检测箱 | 农药残留检测设备 | 食品卫生/温度监控系统 | 食品安全检测试剂 | 天然毒素检测试剂 | 食物中过敏原试剂 | 食品采样工具
折射仪 | 乳品品质分析仪 | 食品包装气体快速检测仪
添加时间:2010-3-3 编辑:C055 阅读:次
Product Name : |
NE8-56S |
Product Description : |
56 Litre Incubator, Fan Assist Circulation New 2009 |
Nominal Tank Capacity : |
56 litre chamber Working capacity of the chamber can be smaller. |
Size selector : |
«Smaller Larger»56 |
Product Specification : |
This Clifton Incubator features precision time and temperature control with programming options from ambient +5°C to 100°C. It can provide fast heating cycles to produce a controlled environment above ambient. Microprocessor control with auto diagnostics, digital LCD display to 0.1°C resolution, three program memory with event log of actual temperature and time data with RS232 interface.
This model a 56 litre capacity Incubator supplied with 2 wire shelves, with the option for additional wire or perforated shelves up to maximum capacity of 5.
Featuring wipe clean touch pad controls illuminated LCD display for viewing wide range of settings, programs, temperature and time values.
The high grade 304 spec stainless steel chamber is sealed shut with a solid door. Other door options available include a window in the door or an internal glass door allowing the observation the chamber with no temperature disturbance.
Temperature
Range: ambient +5°C - 100°C.
Microprocessor control, dual pt100 temperature probes11.
Auto diagnostic system.
Digital LCD display to 0.1°C resolution.
Sensitivity @ 37°C ±0.2°C On wire shelf in middle chamber.
Uniformity @ 37°C ±0.2°C Measured in a vertical axis in the chamber using Wired Shelves.
Calibration Certificate @ 37°C.
Temperature and time programmable
Temperature and time programmable in two ways:
Six segment temperature-time profile with delay start13, heating up9, hold at set point12, each with timers from 1 minute to 99 hours.
Continuous mode at set point with either delay start 13, or timed up to 999 hours12.
Date and time setting, program can start unsupervised13.
Audible alarm and display, setting 0.5°C to 5.0°C about set point10.
Fast temperature rise to attain set point or normal with no overshoot9.
Three program memory, re-called for use.
Event log and program review temperature and time records.
Average minimum and maximum temperature values recorded for each segment of the program for reference and validation.
Manual Air-flap control, adjustable.
Forced air circulation with Fan speed regulation from 10 to 100%.
RS232 interface.
Over-temperature protection
Cass 1, thermal cut out 110°C 7 and separate element overheat protection.
Class 2, experiment/sample protection, adjustable setting above set point, heating switched off, audible and visual indication8.
Accessory options Class 3, temperature protection, self resetting cut outs.
Temperature sensor fail alarm11.
Power failure control with auto resume.
Interior and Case
Using a 304 spec stainless steel interior for long working lfe and easy cleaning.
Case construction stainless steel with powder painted exterior.
With the solid door design there is the option of internal glass door or viewing window in outer door, these options are factory fit items.
|
Internal Dimensions : |
395w x 360d x 395h mm |
External Dimensions : |
590w x 560d x 690h mm |
Temperature Range : |
ambient +5°C to 100°C |
Sensitivity/temperature stability @45°C : |
±0.2°C @ 37°C / ±0.2°C @ 50°C Sensitivity measurements based on temperature readings on shelf in centre of the chamber. |
Uniformity @45°C : |
±0.2°C @ 37°C Uniformity measured in vertical axis in the chamber using Wired Shelves. |
Temperature setting/control : |
Wipe clean controls/Keypad setting/Digital LCD display/Microprocessor control. |
Temperature display resolution : |
Fast realtime display of actual measured temperature in increments of ±0.1°C. |
Warranty Period : |
3 Years |
Safety features : |
Control system diagnostic check on startup.
Over-temperature protection
Cass 1, thermal cut out 110°C 7 and separate element overheat protection.
Class 2, experiment/sample protection, adjustable setting above set point, heating switched off, audible and visual indication8.
Accessory options Class 3, temperature protection, self resetting cut outs.
Temperature sensor fail alarm11.
Power failure control with auto resume. |
Safety Class : |
1 + 2 fitted, options for 3+ |
Power consumption (W) @ 220-240V: |
400W |
Voltage : |
230V |
Packed Weight : |
61kg - palletised |
Packed Dimensions : |
75x73x90cm |
Notes : |
· Before ordering please check the room or building access where this unit will be installed and electrical power requirements.
· Sensitivity measurements based on temperature readings on shelf in centre of the chamber.
· Uniformity measured in vertical axis in the chamber using Wired Shelves.
· Working capacity of chamber can be smaller.
· With the solid door design there is the option of internal glass door to retain chamber temperature and allow viewing or a window can be specified in outer door
· Do not place in direct sunlight and allow a 100mm air gap away from wall at rear. Ensure there is a minimum 300mm air gap from top of the unit to ceiling.
· When no programs are active, the display shows current time and temperature inside chamber. When running a program the display shows program number, temperature inside chamber and status symbol showing the status of heating/cooling. |
产品名称 | 产品简介 | 产品编号 |
---|---|---|
NE8-56S 56升保温箱 | ML-10219-00 |