FGD3本安型CO气体变送器
添加时间:2010-11-12 编辑:X835 阅读:次
- 产品名称:FGD3本安型CO气体变送器
- 产品定货号:MR-08838-00
FGD3本安型CO气体变送器
Features:
• LCD readout
• 4 to 20 milliamp output
• pushbutton calibration
• green flashing 'confidence' LED
• integral sensor for cost sensitive applications
• intrinsically safe
• water and dust proof to IP66
• RFI protected
Specification
Size 122 x 122 x 75mm nominal
Weight 0.65Kg
Gas Types Oxygen / Toxic
Operating Voltage 7 to 30vdc (for 4 to 20 mA signal)
Cable 2 core (plus screen)
Output Signal 0mA - open circuit
2mA – fault.
4mA - zero gas
20mA - full scale gas
22mA - over-range
Max. Cable Loop Resistance Signal - 560 ohms at 24vdc
Sensor Type Electrochemical diffusion
Detection Principle Electrochemical reaction
Operating Temperature - 20 to +40 deg.C
Oxygen - 0 to 99% RH non-condensing
Humidity Range Toxic - 15 to 95% RH non-condensing
Operating Pressure Ambient + or - 10%
United Kingdom Hazardous Area Certification
Standards EN50014, EN50020
BASEEFA Certificate No's Ex97D2288, Code EEx ia IIC T4
Zones 0, 1 & 2
Typical Sensor Characteristics
Gas |
Stock
Number |
Maximum
Range |
Typical
Range Setting |
Expected
Life (in Air) |
Resolution |
Response |
O2 |
SS401 |
0 - 25% vol. * |
0 - 21% vol. * |
2 years |
0.05% vol. |
T95<15 sec |
H2S |
SS402 |
0 – 100ppm |
0 - 50ppm |
2 years |
1ppm |
T90<30 sec |
CO |
SS403 |
0 – 500ppm |
0 - 500ppm |
2 years |
1ppm |
T90<25 sec |
CL2 |
SS404 |
0 – 50ppm |
0 - 20ppm |
2 years |
0.1ppm |
T90<30 sec |
NO2 |
SS405 |
0 – 20ppm |
0 - 20ppm |
2 years |
0.1ppm |
T90<25 sec |
NH3 |
SS406 |
0– 1000ppm |
0 - 100ppm |
1-2 years |
1ppm |
T90<60 sec |
O3 |
SS407 |
0 – 2ppm |
0 - 2ppm |
2 years |
20ppb |
T90<150 sec |
V.O.C. |
SS408 |
0-1000 ppm Detects a range of volatile organic compounds |
SO2 |
SS409 |
0 – 20ppm |
0 - 20ppm |
2 years |
0.1ppm |
T90<35 sec |
NO |
SS410 |
0–250ppm |
0–100ppm |
2 years |
1ppm |
T90<20 sec |
H2 |
SS411 |
0–100%LEL |
0 – 100% LEL |
2 years |
1% LEL |
< 180 sec |
PH3 |
0 – 1ppm |
0– 0.5ppm |
18 months |
1ppb ** |
T90<30 sec |
HCN |
0 – 50ppm |
0 – 25ppm |
2 years |
0.1ppm |
T90<200 sec |
HCL |
0 – 50ppm |
0 - 20ppm |
1 year |
0.1ppm |
T90<120 sec |
|
|
|
|
|
|
|
|
The oxygen instrument is not designed for hazardous area use in oxygen-enriched atmospheres.
Hazardous area applications must be in the range is 0-21%.
** The resolution of the sensor itself is 15ppb.
Typical MCU Control Unit Oxygen and Toxic Alarm Level Settings (Adjustable)
Gas Level 1 Level 2 Level 3 Max. Adjustable FSD
O2 |
19% vol. |
23% vol. |
25% vol. |
25% vol. |
CO |
50ppm |
110ppm |
200ppm |
500ppm |
CL2 |
1ppm |
1.5ppm |
2ppm |
20ppm |
NO2 |
10ppm |
15ppm |
20ppm |
20ppm |
SO2 |
3ppm |
5ppm |
8ppm |
20ppm |
HCL |
1ppm |
1.5ppm |
2ppm |
20ppm |
O3 |
1ppm |
1.5ppm |
2ppm |
2ppm |
H2S |
10ppm |
15ppm |
20ppm |
50ppm |
NH3 |
25ppm |
35ppm |
50ppm |
30ppm |
HCN |
5ppm |
10ppm |
15ppm |
25ppm |
H2 |
20% LEL |
40% LEL |
60% LEL |
0-100% LEL |
NO |
25ppm |
35ppm |
50ppm |
100ppm |
PH3 |
150ppb |
200ppb |
250ppb |
500ppb |