添加时间:2010-2-9  编辑:C055  阅读:次
	

 
        | Hydrogen Sensitivity Range:  0.4% to 5% hydrogen by volume 10% to 125% hydrogen lower flammable limit Accuracy: ± (0.03 x indication + 0.2) percent hydrogen by volume Typical Response Time: T90 of 60 sec maximum Ingress Protection: IP64 capable Calibration Interval: 90 days Product Life Expectancy: 10 years | 
| Power Barrier Input Voltage: 24 VDC nominal  Power Barrier Input Voltage Range: 20 VDC to 28 VDC Intrinsically Safe Sensor Input Voltage: 10 VDC Sensor Input Voltage Range: 5 VDC to 28 VDC Input Power: 10 W Analog Outputs: 4 mA to 20 mA Serial Communication: RS422 | 
| Operating Humidity: 0% to 95% RH  Operating Temperature Range: -20ºC to 40ºC Storage Temperature Range: -40ºC to 50ºC Calibration Background Gas: Air | 
| Intrinsically Safe Power Barrier  4 m Power / Analog Cable | 
| Intrinsically Safe Analog Output Barrier  Intrinsically Safe Serial Interface Barrier 4 m RS422 Serial Interface Cable | 
| 产品名称 | 产品简介 | 产品编号 | 
|---|---|---|
| HY-ALERTA™ 1600氢气分析仪 | MR-06569-00 |