Series 9500氧气和二氧化碳检测器
添加时间:2009-11-6 编辑:读取中…… 阅读:次
- 产品名称:Series 9500氧气和二氧化碳检测器
- 产品定货号:MR-01631-00
The Series 9500 Oxygen and Carbon Dioxide Monitor is designed to provide continuous, unattended monitoring of both oxygen and carbon dioxide.
Features |
Benefits |
State-of-the-Art Sensor Technology |
High Precision Measurement |
Dual Analog Outputs |
Measure Both Gases Simultaneously |
Rapid Speed of Response |
Senses Changes in Seconds |
Economically Priced |
Save Thousands of Dollars vs Other Methods. |
Optional Dual Alarm Relays |
Set Threshold Values |
Minimum Maintenance |
Low Cost of Ownership |
Text Cell |
Text Cell |
System Description
The focal point of the Series 9500 is its state-of-the-art sensor technology. The oxygen sensor features a patented extended life electrochemical sensor with EES (enhanced electrolyte system). EES retards passivation of the sensor anode by allowing the products of oxidation to dissolve in the electrolyte. As a result, sensor life is extended.
Features |
Benefits |
State-of-the-Art Sensor Technology |
High Precision Measurement |
Dual Analog Outputs |
Measure Both Gases Simultaneously |
Rapid Speed of Response |
Senses Changes in Seconds |
Economically Priced |
Save Thousands of Dollars vs Other Methods. |
Optional Dual Alarm Relays |
Set Threshold Values |
Minimum Maintenance |
Low Cost of Ownership |
Text Cell |
Text Cell |
System Description
The focal point of the Series 9500 is its state-of-the-art sensor technology. The oxygen sensor features a patented extended life electrochemical sensor with EES (enhanced electrolyte system). EES retards passivation of the sensor anode by allowing the products of oxidation to dissolve in the electrolyte. As a result, sensor life is extended.
Alpha Omega Instruments has complemented its oxygen sensing capabilities with its next generation NDIR (non-dispersive infrared) measuring system. The carbon dioxide sensor incorporates closed-loop control for enhanced long-term calibration stability. The control signal is generated by means of an optical referencing element that monitors source intensity. This methodology, coupled with a novel source homogenizing gas sampling chamber, yields a system with greatly improved tolerance to changes in the infrared source outputs.
NOW AVAILABLE-EXPLOSION PROOF VERSIONS!
Specifications
OXYGEN
Ranges:
Percent: 0-100, 0-25, 0-10, 0-5, 0-1
Error Band: ±1% of full scale
Response Time: 90% of full scale in less than 20 seconds typical
Sensor Type: Patented Electrochemical Sensor with EES
Operating Humidity Range: 1-99% RH non-condensning
Gas Sample Connections: Quick connect fittings
Sample Delivery: Pressurized sample or optional pump
Alarm Relays: Single alarm relay for oxygen (optional)
Display: 3-1/2 digit LCD for oxygen
Outputs: 4-20 mADC
CARBON DIOXIDE
Ranges:
Percent: 0-20, 0-10, 0-5, 0-1 (special ranges consult factory)
Trace: (parts per million) 0-5,000
Error Band: ±2.0% of full scale or ±5.0% of reading, whichever is greater. For the trace range ±5% full scale or ±95ppm whichever is greater.
Response Time: <35 seconds to 63% of step change @ a sample flow rate of 500ml/minute.
Sensor Type: Non-dispersive infrared(NDIR)
Operating Humidity Range: 5-95% RH non-condensing
Gas Sample Connections: Quick connect fittings
Sample Delivery: Pressurized sample or optional pump
Alarm Relays: Single alarm relay for carbon dioxide (optional)
Display: 3-1/2 digit LCD for carbon dioxide
Outputs: 4-20 mADC
GENERAL SPECIFICATIONS
Power Requirements: 24 VDC (supplied through an AC/DC wall mounted adapter)
Ambient Temperature Range: 40-100°F (5-38°C)
Sample Pressure Limits: <1.0 psig.
Enclosure: NEMA 1, general purpose polycarbonate enclosure suitable for bench-top use
Enclosure Dimension: 11.4" H x 6.3" W x 5.0" D
Warranty: Two years electronics, one year for sensors
Weight: <3 pounds (uncrated)