series3510氧气分析仪
添加时间:2009-10-30 编辑:读取中…… 阅读:次
- 产品名称:series3510氧气分析仪
- 产品定货号:MR-00921-00
Features |
Benefits |
Wide Number of Ranges |
Measure from <1ppm to 10,000 ppm Oxygen |
Exceptional Speed of Response |
Responds Instantaneously to Changes in Oxygen |
Rugged and Versatile Construction |
NEMA 4 Housing Withstands Harsh Environments |
Economically Priced |
Save Thousands of Dollars vs Other Methods |
Patented Electrochemical Sensor |
Offers Exceptional Accuracy and Stability |
Sealed Sensor |
Eliminates Having to Handle Liquid Caustic |
System Description
The Series 3500 Trace Oxygen Transmitter features an advanced electrochemical oxygen sensor that provides exceptional performance, accuracy, and stability. In addition, the enhanced mechanical design of the sensor ensures longer life, and virtually eliminates leakage of caustic electrolyte, a nagging problem associated with sensors that require periodic electrolyte maintenance. And, because the sensor is sealed, it is not position sensitive. In addition, Alpha Omega Instruments oxygen sensors are temperature compensated to provide optimum performance over a wide range of operating conditions.
The Series 3510 Trace Oxygen Transmitter is both dustproof and waterproof, and is rated for NEMA 4 (IP66) service. The instrument is powered from 115VAC, 60Hz, and provides a 4-20 mADC output that can be transmitted to a datalogger, recorder, PLC, DCS, etc. Internal shielding of the electronics offers excellent protection from EMI/RFI noise. Accessories for the Series 3510 Trace Oxygen Transmitter include a pressure regulator, in-line sample filter, and sample pump (shown in upper photo).
The Series 3510 Trace Oxygen Transmitter features an advanced electrochemical oxygen sensor that provides exceptional performance, accuracy, and stability. In addition, the enhanced mechanical design of the sensor ensures longer life, and virtually eliminates leakage of caustic electrolyte, a nagging (and expensive) problem associated with sensors that require periodic electrolyte maintenance. And, because the sensor is sealed, it is not position sensitive. In addition, the Series 3510 Trace Oxygen Transmitter does not require an adjustment in readings when the gas composition changes as do some other analyzers. The output from the sensor is temperature corrected to provide optimum performance over a wide range of operating conditions.
Back To Top
Specifications
Measurement Ranges (parts per million): 0-10, 0-50, 0-100, 0-500, 0-1,000, 0-5,000 and 0-10,000 (special ranges available upon request)
Accuracy: ±1% of full scale
Linearity: ±1% of full scale
Response Time: 90% of full scale in less than 10 seconds typical
Sensor Type: Patented Electrochemical Sensor
Temperature Compensation: Standard
Operating Temperature Range: 40° - 100°F (5° to 38°C)
Sample Gas Pressure Limits: 0.1 to 1.0 psig (1.04 kg/cm² to 1.10 kg/cm²)
Sample Flow Rate: 1.0 to 2.0 SCFH (0.5 to 1.0 liters/min.)
Electrical Input/Output: 14-32 VDC @ 4-20 mADC