GTR 196气体传送器
添加时间:2009-10-29 编辑:读取中…… 阅读:次
- 产品名称:GTR 196气体传送器
- 产品定货号:MR-00804-00
The gas transmitter ADOS GTR 196 is suitable for continuous measurement of gases in normal areas and areas where there is a risk of explosion.
By employing 5 different types of sensor, noxious, explosive and non-combustible gases and vapours can be measured.
A current signal is generated that is proportional to the measured concentration of gas, which is transmitted to an evaluation unit placed in a safe area, away from any dangers of explosion.
The type test of the explosion-protected gas transmitter, is completed by the KEMA.
Test certificate: KEMA 03 ATEX 2403 X
Degree of protection: II 2 G, Ex demb [ia] IIC T6
Type |
TGS |
VQ |
GOW |
Measurement method |
Semiconductor |
Heat reduction |
Thermal conductivity |
Measurement range |
ppm ranges to 100 % LEL |
ppm ranges to 100 % LEL |
from 0 - 5 Vol % to 0 - 100 Vol % |
Percentage error of f.s.d. |
± 5% |
± 5% |
± 3% |
Temperature range |
-4 °F to +113 °F |
-4 °F to113 °F |
-4 °F to +113 °F |
Temperature effect |
5 % |
2 % |
2 % |
Response time (t90) |
approx. 20 s |
approx. 20 s |
approx. 40 s |
Pressure effect(atm.) |
1 % |
1 % |
1 % |
Mounting position |
optional |
optional |
optional |
Application |
Poisonous, combustible and explosive gases in the LEL region |
Poisonous, combustible and explosive gases in the LEL region |
Gases exhibiting substantial differences in thermal conductivity, compared to air |
Versions available |
Single, industrial and Ex-versions |
Single, industrial and Ex-versions |
Single, industrial and Ex-versions |
Service life of the sensor |
unlimited, when used for gases not causing catalytic poisoning |
unlimited, when used for gases not causing catalytic poisoning |
unlimited, when used with gases that do not attack aluminium, rhenium-tungsten or gold |
Supply voltage |
15 V - 30 V |
15 V - 30 V |
15 V - 30 V |
Interfaces |
3-wire techniques, 4-20mA or LON® four-wire techniques, galvanically isolated, data transmission 78 kbps |
3-wire techniques, 4-20mA or LON® four-wire techniques, galvanically isolated, data transmission 78 kbps |
3-wire techniques, 4-20mA or LON® four-wire techniques, galvanically isolated, data transmission 78 kbps |
Protection
Ex-Version |
II 2 G
Ex demb [ia] IIC T6 KEMA 03 ATEX 2403 X |
II 2 G
Ex demb [ia] IIC T6 KEMA 03 ATEX 2403 X |
II 2 G
Ex demb [ia] IIC T6 KEMA 03ATEX2403X |
Protection class |
IP 54 |
IP 54 |
IP 54 |
Dimensions (W x H x D) |
4 x 7 x 3 inch |
4 x 7 x 3 inch |
4 x 7 x 3 inch |
Weight |
2.4 lb |
2.4 lb |
2.4 lb |
Type |
TOX |
IR |
Measurement method |
Electro-chemical cell |
Infrared |
Measurement range |
ppm ranges to 100 LEL % |
0–100 % LEL CH4, C3H8, C2H2 0–100 Vol % CH4 0–1, 2, 3, 4, 5 Vol % CO2 |
Percentage error of f.s.d. |
± 3% |
± 3 % |
Temperature range |
-4 °F to +113 °F |
-4 °F to +113 °F |
Temperature effect |
2 % |
approx. 8 % |
Response time (t90) |
< 60 s |
< 30 sec. |
Pressure effect(atm.) |
1 % |
1 % |
Mounting position |
optional |
optional |
Application |
O2, CO, NH3, NO2, SO2, H2S a.o. |
CH4 (Vol %; LEL) Propane (LEL) CO2 (Vol %) |
Versions available |
Single, industrial and Ex-versions |
Industrial and Ex-versions |
Service life of the sensor |
12 months to 5 years depending on the measuring cell |
approx. 5 years |
Supply voltage |
15 V - 30 V |
15 V – 30 V |
Interfaces |
3-wire techniques, 4-20mA or LON® four-wire techniques, galvanically isolated, data transmission 78 kbps |
3-wire techniques, 4–20 mA or LON® 4-wire techniques, galvanically isolated, data transmission 78 kbps |
Protection
Ex-Version |
II 2 G Ex demb [ia] IIC T6 KEMA 03 ATEX 2403 X |
II 2 G Ex demb [ia] IIC T6 KEMA 03 ATEX 2403 X |
Protection class |
IP 54 |
IP 54 |
Dimensions (W x H x D) |
4 x 7 x 3 inch |
3.94 x 7.08 x 3.15 inch |
Weight |
2.4 lbs |
2.42 lbs |