SensAlert Combustible Gas IR Sensor -- 111255-D-1可燃气体传感器
        添加时间:2009-10-23  编辑:读取中……  阅读:次
	
	
        
        
        
        
          
            - 产品名称:SensAlert Combustible Gas IR Sensor -- 111255-D-1可燃气体传感器
- 产品定货号:MR-00581-00
 
        
       
      
        Minimum Indicated Concentration .............. 4 %LEL
Repeatability .............................................. ± 2% of reading
Accuracy * ................................................. ± 2% of full scale
Zero Drift ................................................... 5% change per year (typical)
Span Drift .................................................. 10% change per year (typical)
Response Time (Rise) ................................. T50: < 6 seconds, (typical)
T90: < 20 seconds, successive exposures
Temperature Range ................................... -20° to 55°C (-4° to 131°F)**
Humidity Range (continuous) ...................... 5–95 %RH, non-condensing
Humidity Range (intermittent†) ................... 0–99 %RH, non-condensing
Pressure Range .......................................... Ambient atmospheric, ± 1 psi
Recommended Calibration Flow rate .......... 1.0 LPM
See More Product Information:  
Specifications
| Sensor Technology  | Infrared  | 
| Measurement Type  | 
| Number of Gases Monitored  | Multi  | 
| Measurement Type  | %LEL or %LFL  | 
| Gas Types  | Combustible; Hydrocarbons (0-100%LEL)  | 
| Features  | Intrinsically Safe  | 
| Environment  | 
| Operating Temperature  | -4 to 131 F  | 
| Operating Humidity  | 5 to 95 %  | 
Minimum Indicated Concentration .............. 4 %LEL
Repeatability .............................................. ± 2% of reading
Accuracy * ................................................. ± 2% of full scale
Zero Drift ................................................... 5% change per year (typical)
Span Drift .................................................. 10% change per year (typical)
Response Time (Rise) ................................. T50: < 6 seconds, (typical)
T90: < 20 seconds, successive exposures
Temperature Range ................................... -20° to 55°C (-4° to 131°F)**
Humidity Range (continuous) ...................... 5–95 %RH, non-condensing
Humidity Range (intermittent†) ................... 0–99 %RH, non-condensing
Pressure Range .......................................... Ambient atmospheric, ± 1 psi
Recommended Calibration Flow rate .......... 1.0 LPM
See More Product Information:  
Specifications
| Sensor Technology  | Infrared  | 
| Measurement Type  | 
| Number of Gases Monitored  | Multi  | 
| Measurement Type  | %LEL or %LFL  | 
| Gas Types  | Combustible; Hydrocarbons (0-100%LEL)  | 
| Features  | Intrinsically Safe  | 
| Environment  | 
| Operating Temperature  | -4 to 131 F  | 
| Operating Humidity  | 5 to 95 %  |