泰亚赛福 —— 世界领先的检测仪器集成供应商
努力为您创造价值
智能 编号 品牌
单一气体检测仪
产品导航
 您当前的位置:气体检测 >> 单一气体检测仪 >> 氧气检测仪(O2) >> PT395 Series有毒气体/氧气传感器

PT395 Series有毒气体/氧气传感器

添加时间:2009-10-21 编辑:读取中…… 阅读:

  • 产品名称:PT395 Series有毒气体/氧气传感器
  • 产品定货号:MR-00210-00
  • 产地:美国
  • 推荐:
Features
Microprocessor based modular design
Electrochemical Sensor Technology
Industry standard 4-20mA output
Field adjustable Alarm level
Single point Non-Intrusive calibration
Bright 3 digit LED display
Displays gas concentration in ppm, calibration prompts and sensor fault codes
Suitable for use in Hazardous Location
Description
Model PT395 Series is a microprocessor-based sensor for the detection of toxic gas in ambient air. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas.
The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a transmitter board assembly. All of the sensor electronics are enclosed in an explosion proof instrument box. The unit’s modular design allows easy maintenance, troubleshooting and high reliability.
The unit provides a fully programmable alarm relay and a linear 4-20mA signal proportional to 0 to 100% of the detection range of the sensor.
The sensor transmitter board includes a three (3) digit LED display for continuous indication of the gas concentration. The calibration mode, alarm and fault status of the sensor are also indicated on the digital display. In the normal operating mode the digital display and 4-20mA reading is proportional to the gas concentration detected by the sensor. In the calibration mode the digital display indicates the calibration status, alarm relay output is inhibited and analog signal output is set to 2 mA to avoid any false alarm by the control monitor. In the sensor fault mode the transmitter drops the output signal to < 1 mA.
Specifications
Sensor Type
Electrochemical
Measuring Ranges
 
Ammonia (NH3)
50 ppm
Carbon Monoxide (CO)
100 & 1000 ppm
Chlorine (CL2)
10 ppm
Chlorine Dioxide (CLO2)
50 ppm
Ethylene (C2H4)
100 pm
Ethylene Oxide (C2H4O)
50 ppm
Hydrogen Chloride (HCL)
20 ppm
Hydrogen Sulfide (H2S)
100 ppm
Hydrogen (H2)
100 & 1000 ppm
Hydrogen Cyanide (HCN)
30 ppm
Methyl Mercaptan (CH3SH)
100 ppm
Nitrogen Dioxide (NO2)
20 ppm
Nitric Oxide (NO)
100 ppm
Oxygen Deficiency (O2)
25%
Sulfur Dioxide (SO2)
50 ppm
Repeatability
± 2 % Full scale
Zero Drift
< 5% per year
Response Time
T90 < 30 seconds with 100% FS gas applied
Classification
Class I, division 1, Groups B,C & D
Operating Temperature
-4°F to +122°F (-20°C to +50°C)
Operating Humidity
15% to 90% RH, non-condensing
Display
Bright 3 digit LED display
Approvals
CSA / AT
Features
Microprocessor based modular design
Electrochemical Sensor Technology
Industry standard 4-20mA output
Field adjustable Alarm level
Single point Non-Intrusive calibration
Bright 3 digit LED display
Displays gas concentration in ppm, calibration prompts and sensor fault codes
Suitable for use in Hazardous Location
Description
Model PT395 Series is a microprocessor-based sensor for the detection of toxic gas in ambient air. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas.
The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a transmitter board assembly. All of the sensor electronics are enclosed in an explosion proof instrument box. The unit’s modular design allows easy maintenance, troubleshooting and high reliability.
The unit provides a fully programmable alarm relay and a linear 4-20mA signal proportional to 0 to 100% of the detection range of the sensor.
The sensor transmitter board includes a three (3) digit LED display for continuous indication of the gas concentration. The calibration mode, alarm and fault status of the sensor are also indicated on the digital display. In the normal operating mode the digital display and 4-20mA reading is proportional to the gas concentration detected by the sensor. In the calibration mode the digital display indicates the calibration status, alarm relay output is inhibited and analog signal output is set to 2 mA to avoid any false alarm by the control monitor. In the sensor fault mode the transmitter drops the output signal to < 1 mA.
Specifications
Sensor Type
Electrochemical
Measuring Ranges
 
Ammonia (NH3)
50 ppm
Carbon Monoxide (CO)
100 & 1000 ppm
Chlorine (CL2)
10 ppm
Chlorine Dioxide (CLO2)
50 ppm
Ethylene (C2H4)
100 pm
Ethylene Oxide (C2H4O)
50 ppm
Hydrogen Chloride (HCL)
20 ppm
Hydrogen Sulfide (H2S)
100 ppm
Hydrogen (H2)
100 & 1000 ppm
Hydrogen Cyanide (HCN)
30 ppm
Methyl Mercaptan (CH3SH)
100 ppm
Nitrogen Dioxide (NO2)
20 ppm
Nitric Oxide (NO)
100 ppm
Oxygen Deficiency (O2)
25%
Sulfur Dioxide (SO2)
50 ppm
Repeatability
± 2 % Full scale
Zero Drift
< 5% per year
Response Time
T90 < 30 seconds with 100% FS gas applied
Classification
Class I, division 1, Groups B,C & D
Operating Temperature
-4°F to +122°F (-20°C to +50°C)
Operating Humidity
15% to 90% RH, non-condensing
Display
Bright 3 digit LED display
Approvals
CSA / AT
 

产品名称产品简介产品编号
PT395 Series Toxic & Oxygen SensorMR-00210-00



相关产品