GasAlertClip Extreme 2 & 3单一气体检测仪
添加时间:2009-10-20 编辑:C065 阅读:次
- 产品名称:GasAlertClip Extreme 2 & 3单一气体检测仪
- 产品定货号:MR-00198-00
Single Gas Monitor
The GasAlertClip Extreme offers unequaled protection in two and three year versions, with no sensor replacement, no calibration and no downtime. With zero maintenance costs and continuous around the clock monitoring, the GasAlertClip Extreme is a cost effective solution. Also compatible with the MicroDock II automatic test and calibration system.
- Simple operation梠ne-button activation, test and data transmission
- Continuous, alphanumeric, status LCD shows detector life remaining, alarm setpoints and advises self-test status
- Built-in concussion-proof boot
- Records and displays the peak alarm encountered and the time elapsed since the exposure occurred
- Automated bump test with BW抯 MicroDock II system
- Automatic event logging records 10 most recent alarm events; downloadable to a printer, computer or MicroDock II
- Loud (95 dB typical) audible alarm, bright, quad-LED indicators and internal vibrator alarm come standard
- Compact and lightweight
- Rugged, IP 66/67 highly water-resistant design
- Full function self-test of audible/visual and vibrator alarms, integrity of sensor, battery and circuitry
Simply press the START/TEST button and the GasAlertClip Extreme is ready to use, providing two or three years of continuous, maintenance-free operation from the day of activation.
The GasAlertClip Extreme is highly waterresistant, with an IP66/67 housing, fully immersible to a depth of one meter. The GasAlertClip Extreme抯 housing includes a integral concussion-proof boot and a heavy-duty, stainless steel, alligator style belt-clip. A large easy-to-read LCD shows detector life remaining, the two alarm setpoints and peak alarm exposures.
The detector抯 life remaining is displayed in months, days and then hours. A fullfunction self-test verifi es sensor, circuitry and battery integrity as well as function of the audible, visual and vibrator alarms.
Stored data can be transmitted directly by IR link to a cordless infrared printer for immediate printout, to a MicroDock II docking station module or to a personal computer via an IR adaptor connected to the computer抯 USB port.
Simply clip the GasAlertClip Extreme to your lapel, pocket, belt or hard-hat for unequaled, cost-effective protection.
Gas Monitored |
H2S |
CO |
SO2 |
O2 |
Sensor Range |
0-100 ppm |
0-300 ppm |
0-100 ppm |
0-30.0 % by vol |
Low Alarm Level |
10 ppm |
35 ppm 30 ppm (UK/EU) |
5 ppm |
19.5% |
High Alarm Level |
15 ppm |
200 ppm |
10 ppm |
23.5% |
Operaing Temperature |
Internal vibrator operates to +5癋 / -15癈
|
Calibration |
Not Required |
Self-Calibrating |
General Specifications:
Rugged composite material with integral concussion-proof boot
Humidity: 5% to 95% RH (non-condensing)
EMI/RFI: Complies with EMC Directive 89/336/EEC
Ingress protection: IP 66/67
Battery: Lithium, non-replaceable
Continuously on: Yes
One-button control: Activation, self-test and alarm event data transmission
Full functional self-test: Verifi es integrity of sensor, circuitry, battery and audible/visual alarms
Sensor: Electrochemical cell (temperature compensated)
Operational life: Two years (H2S, CO, SO2 or O2) or three years (H2S or CO)
Indicators and Alarms:
Visual alarm: Flashing, wide-angled alarm lens with red quad-LEDs, plus flashing ALARM icon
Audible alarm: Pulsing, high-output siren at 95 dB (typical) at 1 ft. (0.3 m)
Vibrator alarm: Internal
Failure alarm: Yes (audible/visual/vibration)
Self-test pass: Yes (audible/visual/vibration)
Other: End of life (audible/visual/vibration)
Continuous LCD Display:
Life remaining: Continuously displayed in months, days, then hours
Two alarm levels: LOW alarm / HIGH alarm
Peak alarm exposure: Records and displays peak alarm exposure value and time elapsed (up to 24 hours)
Alarm setpoints: High and low (displayed on demand in ppm or %)
Self-test status: Advises to "TEST" and that self-test was passed
Tests:
Full function self-test: On activation and every 20 hours
Battery: Every two hours (auto)
Event Logging:
Records and transmits up to 10 gas alarm events
Event information: Gas type, peak exposure level (ppm or %); alarm duration in minutes and seconds; time elapsed since the alarm occurred in days, hours and minutes, life remaining, serial number, self-tests performed, total number and duration of all events encountered
Transmission method: Via infrared port to infrared printer or to an IR DataLink
Physical Size:
Size: 1.1 x 2.0 x 3.2 in. / 28 x 50 x 81 mm
Weight: 2.7 oz. / 76 g
Warranty: 2 or 3 years from activation (given normal operation); 1-year shelf life