        Microprocessor based modular design 
Electrochemical Sensor Technology 
Industry standard 4-20mA output 
Field adjustable Alarm level 
Single point Non-Intrusive calibration 
Bright 3 digit LED displa
Model PT295-H2S is a microprocessor-based sensor designed to detect hydrogen sulfide in parts per million (ppm) level. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas. 
y 
Displays gas concentration in ppm, calibration prompts and sensor fault codes 
Class I, Div 1, Suitable for use in Hazardous Location 
Description
Model PT295-H2S is a microprocessor-based sensor designed to detect hydrogen sulfide in parts per million (ppm) level. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas. 
The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a transmitter board assembly. All of the sensor electronics are enclosed in an explosion proof instrument box. The unit’s modular design allows easy maintenance, troubleshooting and high reliability. 
The unit provides a 4-20mA signal proportional to 0 to 100% of the detection range of the sensor and a fully programmable alarm relay. 
The sensor transmitter board includes a three (3) digit LED display for continuous indication of the gas concentration. The calibration mode, alarm and fault status of the sensor are also indicated on the digital display. In the normal operating mode the digital display and 4-20mA reading is proportional to the gas concentration detected by the sensor. In the calibration mode the digital display indicates the calibration status, alarm relay output is inhibited and analog signal output is set to 2 mA to avoid any false alarm by the control monitor. In the sensor fault mode the transmitter drops the output signal to < 1 mA. 
Specifications
Sensor Type 
Electrochemical 
Measuring Range 
0 to 100 parts per million (ppm) 
Repeatability 
± 2 % Full scale 
Zero Drift 
< 5% per year 
Response Time 
T90 < 30 seconds with 100% FS gas applied 
Classification 
Class I, division 1, Groups B, C & D 
Operating Temperature 
-4°F to +158°F (-20°C to +70°C) 
Operating Humidity
15% to 90% RH, non-condensing 
Mechanical Specifications 
Length: 7 inches (178 mm) 
Width: 5 inches (127 mm) 
Height: 4.5 inches (114 mm) 
Display 
Bright 3 digit LED display 
Status Indicators 
Three-digit display for gas concentration, 
Alarm relay status, calibration mode and 
sensor fault status. 
Approvals 
ABS Type approved 
CSA / ATEX for use in Hazardous 
Locations 
CSA Standard C22.2 No 30-M1985 & 
C22.2 No 142-M1987 
Input Power
14-28 VDC. 24 VDC nominal 
Power Consumption
< 1.5 Watt. Typical 50mA @ 24 VDC 
Alarm Relays
Fully programmable. 0 to Full scale 
range of the sensor. Latching or Non- 
Latching. 
Relay Ratings
SPDT Form “C” type Relay contacts 
5 Amps @ 250 VAC or 30 VDC 
Analog Output
Linear 4-20mA (300 Ohms max. load) 
2.0 mA - Calibration mode 
< 1.0 mA - Sensor malfunction 
Calibration
Non-Intrusive activated by internal