PCA®2燃烧分析仪
添加时间:2009-10-30 编辑:C055 阅读:次
- 产品名称:PCA®2燃烧分析仪
- 产品定货号:MR-00914-00
The PCA®2 is a commercial grade, handheld combustion and emissions analyzer for sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. The PCA®2 is the perfect tool for service technicians and boiler contractors who need to ensure safe operating conditions, determine combustion efficiency, or perform emissions testing in combustion applications.
The PCA®2 directly measures and displays flue gas Oxygen (O2), Carbon Monoxide (CO), Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature and optionally measures and displays Nitric Oxide (NO), Nitrogen Dioxide (NO2) and Sulfur Dioxide (SO2). Simultaneously, the PCA®2 calculates and displays combustion efficiency (EFF), Excess Air (EA), Carbon Dioxide (CO2), NOx and Oxygen reference values. The PCA®2 performs combustion calculations for ten fuels including, Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, Bagasse and Digester Gas. The large backlit graphic displays shows eight different measurements and calculated values simultaneously, and also has zoom capabilities.
Features & Benefits
Smart Sensors
Field replaceable
Pre calibrated
Easy access
Quick and accurate response
Measures 4 Gases Simultaneously
Standard - O2, CO-H2
Optional - CO (high), NO, NO2 & SO2
Automatic CO Overrange Protection
Versatile Power Management
Disposable batteries
Rechargeable batteries
Optional universal power supply
Graphic Display
160 x 160 graphic liquid crystal display
Easy to read
Backlit
Zoom
Specifications:
Measurement Ranges |
Primary/Ambient Air Temperature |
-4° to 999°F |
Stack Temperature |
-4° to 2192°F |
Oxygen |
0 to 20.9% |
Carbon Monoxide (H2 comp) |
0 to 4,000 ppm |
Carbon Monoxide, high range |
4,001 to 20,000 ppm |
Nitric Oxide |
0 to 3,000 ppm |
Nitrogen Dioxide |
0 to 500 ppm |
Sulfur Dioxide |
0 to 5,000 ppm |
Pressure/Draft |
-72 to +72 inwc |
Calculated Ranges |
Combustion Efficiency |
0.1 to 100% |
Excess Air |
1.0 to 250% |
Carbon Dioxide (dry basis) |
0 to fuel dependent maximum |
NOx (NOx = NO + NO2) |
0 to 3,500 ppm |
NOx referenced to % O2 |
0 to 9,999 ppm |
CO referenced to % O2 |
0 to 9,999 ppm |
NO referenced to % O2 |
0 to 9,999 ppm |
NO2 referenced to % O2 |
0 to 9,999 ppm |
SO2 referenced to % O2 |
0 to 9,999 ppm |
Accuracy |
Oxygen |
± 0.3% O2 (on flue gas) |
Stack or Flue Gas Temperature |
± 4°F between 32 and 255°F (± 2°C between 0 and 124°C) |
± 6°F between 257 and 480°F (± 3°C between 125 and 249°C) |
± 8°F between 482 and 752°F (± 4°C between 250 and 400°C) |
Primary-air/Ambient Temperature |
± 2°F between 32 and 212°F (± 1°C between 0 and 100°C) |
Pressure/Draft |
± 2% reading or 0.02 inwc whichever is greater between 0 and ± 10 inwc |
± 3% of reading between ± 10 and ± 72 inwc |
CO |
± 5% of reading or ± 10 ppm whichever is greater between 0-2000 ppm CO |
± 10% of reading between 2001 to 20,000 ppm |
NO |
± 5% of reading or ± 5 ppm whichever is greater between 0-2000 ppm NO |
NO2 |
± 5% of reading or ± 5 ppm whichever is greater between 0-500 ppm NO2 |
SO2 |
± 5% of reading or ± 10 ppm whichever is greater between 0-2000 ppm SO2 |
Specifications: (continued)
Memory |
500 complete combustion test records |
Logged Memory |
500 complete logged combustion test records |
Selectable Fuels |
Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, Bagasse and Digester Gas |
Size |
9"H x 3"W x 2.5" (22.9 cm x 7.6 cm x 6.3 cm) |
Weight |
1.4 lbs (0.6 kg) |
Power Source |
Four disposable AA alkaline batteries or NiMH rechargeable batteries providing 10 hours of continuous operation. Optional AC power adapter |
Display |
160 x 160 (2.5 in x 2.5 in) Graphic Liquid Crystal Display |
Warm Up Time |
60 second total warm up time (sensors are checked and autozeroed during warm up) |