风速检测仪
添加时间:2009-10-21 编辑:读取中…… 阅读:次
- 产品名称:风速检测仪
- 产品定货号:MB-00086-00
AirGard® Air Velocity Monitor
Provides constant reading of air velocity for easy monitoring of cleanroom performance
Audible and visual alarms let you know when air speed falls below 90 fpm (or other critical velocity)
Flush mounts to Terra Modular Cleanroom control panel, laminar flow hoods, and other enclosures
Easy to field calibrate
This flush-mount air velocity monitor allows you to monitor the vertical speed of air inside a cleanroom, hood or other enclosure.
Its dual setpoint capability enables you to determine critical high/low air speed thresholds. When the air speed exceeds the “safe” range, the AirGard® issues audible and visual alarms to alert you to a clogged filter or other problem. Price includes installation in specified cleanroom or hood. Includes relay output, remote alarm, high flow alarm disable, and emergency purge.
Specifications |
Dimensions: |
5.25"L x 3.0"W x 0.625"D (face plate) 3.0"L x 2.0"W x 0.5"D (rear enclosure) |
Display/Alarm Range: |
50 - 250 fpm (0.25 - 1.27 m/s) |
Alarm Delays: |
User configurable through menu |
Units: |
English and Metric (user-selectable) |
Visual Display: |
Analog bargraph:Red zone - alarm Yellow zone - marginal Green zone - normal Jumbo LEDs (digital LCD can be enabled) |
|
Alarm Indications: |
Jumbo red LED and audible alarm (85 dB @ 4") |
Calibration: |
2-point field calibration |
Accuracy: |
± 10% or 10 fpm, whichever is greater |
Storage Temperature: |
-40 to +150°F (-40 to +65°C) |
Operating Temperature: |
55 to 86°F (13 to 30°C) |
Power Requirements: |
9-30V AC/DC |
AirGard® Air Velocity Monitor
Provides constant reading of air velocity for easy monitoring of cleanroom performance
Audible and visual alarms let you know when air speed falls below 90 fpm (or other critical velocity)
Flush mounts to Terra Modular Cleanroom control panel, laminar flow hoods, and other enclosures
Easy to field calibrate
This flush-mount air velocity monitor allows you to monitor the vertical speed of air inside a cleanroom, hood or other enclosure.
Its dual setpoint capability enables you to determine critical high/low air speed thresholds. When the air speed exceeds the “safe” range, the AirGard® issues audible and visual alarms to alert you to a clogged filter or other problem. Price includes installation in specified cleanroom or hood. Includes relay output, remote alarm, high flow alarm disable, and emergency purge.
Specifications |
Dimensions: |
5.25"L x 3.0"W x 0.625"D (face plate) 3.0"L x 2.0"W x 0.5"D (rear enclosure) |
Display/Alarm Range: |
50 - 250 fpm (0.25 - 1.27 m/s) |
Alarm Delays: |
User configurable through menu |
Units: |
English and Metric (user-selectable) |
Visual Display: |
Analog bargraph:Red zone - alarm Yellow zone - marginal Green zone - normal Jumbo LEDs (digital LCD can be enabled) |
|
Alarm Indications: |
Jumbo red LED and audible alarm (85 dB @ 4") |
Calibration: |
2-point field calibration |
Accuracy: |
± 10% or 10 fpm, whichever is greater |
Storage Temperature: |
-40 to +150°F (-40 to +65°C) |
Operating Temperature: |
55 to 86°F (13 to 30°C) |
Power Requirements: |
9-30V AC/DC |