ACD-20SW旋转钳形表
添加时间:2011-4-26 编辑:603 阅读:次
- 产品名称:ACD-20SW旋转钳形表
- 产品定货号:ME-07722-00
Model: ACD-20SW Swivel Clamp Meter,ACD-20SW旋转钳形表
New patented rotating head clamp design allows easy viewing of the measurements in tight or inconvenient to reach places. Simply rotate the body of meter to get an unobstructed view of the LCD display. Reach set of features and CAT III 600V safety reading for use in electrical and HVAC applications.
180 degree rotating head for the perfect display viewing
Advanced VoltTect non-contact voltage detection
Slim jaw design with one hand operation
Measures AC Current up to 400 ACA, AC/DC Voltage up to 600V, Resistance and Capacitance
Audible continuity
Auto and manual ranging respectively for quick checks and precise measurements
Auto power off
Data hold
Diode Test
Accommodates conductors up to 1.18” (30mm) in diameter
Test leads, battery (installed), Users Manual, Carrying Case are included with the product
F E A T U R E S
Battery Life: |
200 hours typical with carbon-zinc.400 hours typical with alkaline. |
Size: |
306 × 135 × 30mm (12 × 5.3 × 1.2 in). |
Weight: |
Approx. 157g (1.26lb) including battery. |
Safety: |
CAT III 600 V, N10140, CE |
S P E C I F I C A T I O N S
Display: |
|
3¾ digit liquid crystal display (LCD) with a maximumreading of 3999. |
Polarity: |
|
Automatic, positive implied, negative polarityindication. |
Overrange: |
|
(OL) or (-OL) is displayed. |
Zero: |
|
Automatic. |
Measurement Rate: |
|
2 times per second, nominal. |
Accuracy: |
|
Stated accuracy at 74°F ±8°F, <75% relativehumidity. |
Jaw Opening Capability: |
|
30mm (1.18 in) conductor. |
Power: |
|
1.5 volt battery x2, R03/SIZE AAA. |
DC Volts Ranges: |
|
400mV, 4V, 40V, 400V, 600V |
Accuracy: |
|
±(0.5% rdg + 2 dgts) |
AC Volts (50hz - 500hz) Ranges: |
|
4V, 40V, 400V, 600V |
Accuracy: |
|
±(1.2% rdg + 5 dgts) ±(1.5% rdg + 5 dgts) on 600V range |
AC Current (50hz - 60hz) Ranges: |
|
40A , 400A |
Accuracy: |
|
±(2.0% rdg + 6 dgts) 50 ~ 60Hz |
Resistance Ranges: |
|
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
Accuracy: |
|
±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges |
Accuracy: |
|
±(1.5% rdg + 4 dgts) on 4MΩrange |
Accuracy: |
|
±(3.0% rdg + 5 dgts) on 40MΩ range |
Continuity Range: |
|
400Ω |
Diode Test Test current: |
|
1.2mA (approximate) |
Accuracy: |
|
±(3.0% rdg + 3 dgts) |
Non-Contact Voltage Indicator: |
|
Sense voltage 70V to 600VAC (50Hz ~ 60Hz) beeper chirps and big bright red LED comes on, works when meter dial is on any ranges. |