6500万用表
        添加时间:2011-4-7  编辑:603  阅读:次
	
	
        
        
        
        
          
            - 产品名称:6500万用表
 
            - 产品定货号:ME-07651-00
 
          
          
          
         
        
       
      
        6500 – Multimeter, 6500 万用表
• 50,000 count and 50 segment bar graph backlit display 
• Basic DC accuracy is ±0.03% 
• RS232 interface with software and cable 
• dBm measurement with 4W to 1200W reference resistances 
• AC and (AC+DC) TRUE RMS measurement 
• Measures frequency, Duty cycle and Capacitance 
• Cat III 1000V 
• Max/Min and Relative measurements 
• Auto power off and backlit display 
 
| 
 | 
| 
 Ranges  | 
 50mV, 500mV  |  
| 
 Best Resolution  | 
 1µV  |  
| 
 Accuracy  | 
 ±(0.03% + 6d)  |  
| 
 Input Impedance  | 
 1G  |   
 | 
| 
 | 
| 
 Ranges  | 
 5V, 50V, 500V, 1000V  |  
| 
 Best Resolution  | 
 100µV  |  
| 
 Accuracy  | 
 ±(0.03% + 6d)  |  
| 
 Max. Input Voltage  | 
 1000V DC  |  
| 
 Input Impedance  | 
 10M  |   
 | 
| 
 | 
| 
 Ranges  | 
 50mV, 500mV  |  
| 
 Best Resolution  | 
 1µV  |  
| 
 AC mV Accuracy  | 
 40Hz to 1Khz: ±(0.5% + 40d), 1KHz to 10KHz: ±(1.0% + 40d), 10KHz to 20KHz: ±(2.5% + 40d)  |  
| 
 Input Impedance  | 
 1G  |   
 | 
| 
 | 
| 
 Ranges  | 
 5V, 50V, 500V, 1000V  |  
| 
 Best Resolution  | 
 100µV  |  
| 
 AC Volts Accuracy (5V to 500V ranges)  | 
 40Hz to 1KHz: ±(0.5% +40d), 1KHz to 10KHz: ±(1.0% + 40d), 10KHz to 20KHz: ±(2.5% + 40d)  |  
| 
 Max. Input Voltage  | 
 1000V DC or AC peak  |  
| 
 Input Impedance  | 
 10M  |   
 | 
| 
 | 
| 
 Ranges  | 
 500µA, 5000µA  |  
| 
 Best Resolution  | 
 10.0nA  |  
| 
 Accuracy  | 
 ±(0.15% + 1d)  |  
| 
 Overload Protection  | 
 0.5A/250V fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 50mA, 500mA  |  
| 
 Best Resolution  | 
 1.0µA  |  
| 
 Accuracy  | 
 ±(0.15% + 10d)  |  
| 
 Overload Protection  | 
 0.5A/250V fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 5A, 10A  |  
| 
 Best Resolution  | 
 100µA  |  
| 
 Accuracy  | 
 ±(0.5% + 10d)  |  
| 
 Overload Protection  | 
 10A/250V fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 500µA, 5000µA  |  
| 
 Best Resolution  | 
 10.0nA  |  
| 
 Accuracy  | 
 ±(0.75% + 10d) 40Hz to 1KHz  |  
| 
 Overload Protection  | 
 0.5A/250V fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 50mA, 500mA  |  
| 
 Best Resolution  | 
 1.0µA  |  
| 
 Accuracy  | 
 ±(0.75% + 20d) 40Hz to 1KHz  |  
| 
 Overload Protection  | 
 0.5A/250V fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 5A, 10A  |  
| 
 Best Resolution  | 
 100µA  |  
| 
 Accuracy  | 
 40Hz to 1KHz 5A: ±(0.75% + 20d) 40Hz to 1KHz 10A: ±(0.75% + 20d)  |  
| 
 Overload Protection  | 
 10A/250V fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 500, 5K, 50K, 500K, 5M, 50M  |  
| 
 Best Resolution  | 
 10.0m  |  
| 
 Accuracy  | 
 ±(0.1% + 5d)  |  
| 
 Max. Input Voltage  | 
 250V  |   
 | 
| 
 | 
| 
 Buzzer  | 
 Will sound at < 60  |   
 | 
| 
 | 
| 
 Ranges  | 
 50nF, 500nF, 5µF, 50µF, 500µF, 5000µF  |  
| 
 Best Resolution  | 
 10pF  |  
| 
 Accuracy  | 
 ±(1.0% + 5d)  |  
| 
 Maximum Input Volts  | 
 250V  |   
 | 
| 
 | 
| 
 Range  | 
 2.5V  |  
| 
 Resolution  | 
 0.1mV  |  
| 
 Accuracy  | 
 ±(1.0% + 5d)  |  
| 
 Test Current  | 
 Approx. 0.7mA  |   
 | 
| 
 | 
| 
 Sensitivity  | 
 +2V to +5V Square wave  |  
| 
 Accuracy  | 
 ±(0.006% + 4d)  |  
| 
 Frequency Range  | 
 5Hz to 2MHz  |   
 | 
| 
 | 
| 
 Ranges  | 
 5Hz to 200KHz  |  
| 
 Best Resolution  | 
 0.001Hz  |  
| 
 Accuracy  | 
 ±(0.006% + 4d)  |  
| 
 Input Sensitivities (Range/Sensitivity)  | 
 (500mV / 0.1V), (5V / 0.5V), (50V / 4V), (500V / 40V), (1000V / 400V), (5000µA / 1000µA), (500mA / 100mA)  |   
 | 
| 
 | 
| 
 Range  | 
 0 to 90%  |  
| 
 Resolution  | 
 0.01%  |  
| 
 Accuracy  | 
 ±10%  |   
 | 
| 
 | 
| 
 Operating Temperature  | 
 0 to 30ºC (32 to 86ºF) @ relative humidity < 80% 31 to 51ºC (87 to 124ºF) @ relative humidity < 50%  |  
| 
 Power  | 
 (6) AAA Batteries  |  
| 
 Size  | 
 7.9" (H) x 3.94" (W) x 1.57" (D)  |  
| 
 Weight  | 
 1.23 lbs  |  
| 
 Accessories  | 