6100万用表
        添加时间:2011-4-7  编辑:C092  阅读:次
	
	
        
        
        
        
          
            - 产品名称:6100万用表
 
            - 产品定货号:ME-07649-00
 
          
          
          
         
        
       
      
        6100 -multimeter, 6100万用表   
• 3 3/4 digit, 4,000 count Back lit display 
• Appropiate input jacks light up when measurement function is selected 
• CAT II 1000V and CAT III 600V input and test leads Safety rating 
• Measures Frequency, Duty cycle and Capacitance 
• Buzzer and flashing light warning when test leads are connected to the wrong input or overload 
• Relative mode and display Hold 
• Resettable current overload fuse, no need to open the meter and replace blown fuse 
 
| 
 | 
| 
 Ranges  | 
 400mV, 4.0V, 40V, 400V and 1000V  |  
| 
 Best resolution:  | 
 100µV  |  
| 
 Accuracy  | 
 ±(0.8% + 2d)1000V range; ±(0.7% + 2d)all other ranges  |  
| 
 Input Impedance  | 
 10M  |  
| 
 Max. input Volts.  | 
 1000V DC or 750V rms  |   
 | 
| 
 | 
| 
 Ranges  | 
 400mV, 4V, 40V, 400V, 750V  |  
| 
 Best Resolution  | 
 100µV  |  
| 
 Accuracy  | 
 ±(3.0% + 3d) 400mV range; ±(1.0% + 3d) 1000V range; ±(0.8% + 3d) all other ranges  |  
| 
 Input Impedance  | 
 10M  |  
| 
 Max. input Volts  | 
 1000V DC or 750V rms  |   
 | 
| 
 | 
| 
 Ranges  | 
 400µA, 4000µA, 40mA, 400mA, 10A   |  
| 
 Best Resolution  | 
 100pA  |  
| 
 Accuracy  | 
 ±(2.0% + 3d) 10A range; ±(1.0% + 3d) all other ranges  |  
| 
 Overload Protection  | 
 0.5A/250Volt resettable fuse and a 10A/250Volt fast blow fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 400µA, 4000µA, 40mA, 400mA and 10A  |  
| 
 Best Resolution  | 
 100pA  |  
| 
 Accuracy  | 
 ±(3.% + 5d) 10A range; ±(1.5% + 7d) all other ranges  |  
| 
 Overload Protection  | 
 0.5A/250V resettable fuse and a 10A/250Volt fast blow fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 400O, 4KO, 40KO, 400KO, 4MO, 40MO  |  
| 
 Best Resolution  | 
 0.1  |  
| 
 Accuracy  | 
 ±(2.0% + 5d) 40MO range; ±(1.2% + 2d) all other ranges  |  
| 
 Open circuit voltage  | 
 Approx. 250mV  |  
| 
 Overload Protection  | 
 250VDC or rms  |   
 | 
| 
 | 
| 
 Ranges  | 
 4nF, 40nF, 400nF, 4µF, 40µF, 200µF  |  
| 
 Best Resolution  | 
 1pF  |  
| 
 Accuracy  | 
 ±(5.0% + 5d) 4nF range; ±(3.0% + 5d) all other ranges  |  
| 
 Overload Protection  | 
 400ma/250V resettable fuse  |   
 | 
| 
 | 
| 
 Ranges  | 
 9.999Hz, 99.99Hz, 999.9Hz, 9.999KHz, 99.99KHz, 199.9KHz  |  
| 
 Best Resolution  | 
 0.001Hz  |  
| 
 Accuracy  | 
 ±(3.0% + 5d) all ranges and unspecified greater than 200KHz  |  
| 
 Overload Protection  | 
 250VDC or rms  |   
 | 
| 
 | 
| 
 Resolution  | 
 0.1%  |  
| 
 Accuracy  | 
 ±3.0%  |   
 | 
| 
 | 
| 
 Open Circuit Volts  | 
 0.5V  |  
| 
 Buzzer will sound  | 
 at less than 50O resistance  |   
 | 
| 
 | 
| 
 Open Circuit Volts  | 
 1.5VDC  |  
| 
 Overload Protection  | 
 250VDC or rms  |   
 | 
| 
 | 
| 
 Base Current  | 
 10µA  |  
| 
 Open Circuit Vce  | 
 2.8V  |   
 | 
| 
 | 
| 
 Operating Temperature  | 
 0 to 40º C ( 32º F to 122º F) with less than 70% humidity  |  
| 
 Dimensions  | 
 7.7" (H) x 3.6" (W) x 2.2" (D) ; 195mm x 92mm x 55mm  |  
| 
 Weight  | 
 14.3 oz  |  
| 
 Power  | 
 3 x 1.5V AAA Batteries  |  
| 
 Accessories  | 
 Test leads, Operator's manual and Batteries  |   
 |