Selection & Specification Data
Generic
Coal Tar
Description
Ultra-high build, single-component coal tar mastic for protecting steel and concrete substrates subject to aggressive conditions and for below grade damp proofing requirements.
Features
Application up to 30 dry mils (750 microns) in a single coat.
Self priming, single-coat capabilities.
Excellent corrosion resistance.
Complies with MIL-C-18480-B and Bureau of Reclamation CA50 specifications.
Color
Black (0900)
Finish
Low gloss.=
Primers
Self-priming
Topcoats
Not recommended
Dry Film Thickness
18.0 mils (450 microns) in one or two coats.
Total dry film thickness less than 12 mils (300 microns) or in excess of 30 mils (750 microns) not recommended.
Solids Content
By volume: 68% ± 2%
Theoretical Coverage Rate
1090 mil ft2 (26.7 m2/l at 25 microns).
Allow for loss in mixing and application
Nominal VOC Values
As supplied: 3.0 lbs./gal (360 g/l)
Thinned: 12 oz/gal w/ Thinner #10, 3.5 lbs./gal (417 g/l)
Dry Temperature Resistance
Continuous: 350°F (177°C)
Non-continuous: 400°F (204°C)
Wet Temperature Resistance
Immersion temperature should not exceed 120°F (49°C).
Limitations
Do not use for potable water requirements.
Substrates & Surface Preparation
General
Surfaces must be clean and dry. Employ adequate methods to remove dirt, dust, oil and all other contaminants that could interfere with adhesion of the coating.
Steel
Immersion: SSPC-SP10
Non-Immersion: SSPC-SP6 for maximum protection. SSPC-SP2 or SP3 as minimum requirement.
Surface Profile: 2.0-3.0 mils (50-75 micron)
Galvanized Steel
Non-Immersion: Sweep blast to roughen surface and produce a 1.0-2.0 (25-50 micron) profile.
Concrete
Concrete must be cured 28 days at 75° F (24° C) and 50% relative humidity or equivalent. Prepare surfaces in accordance with ASTM
D4258 Surface Cleaning of Concrete and ASTM D4259 Abrading Concrete. Voids in concrete may require surfacing.
Application Equipment
Listed below are general equipment guidelines for the application of this
product. Job site conditions may require modifications to these guidelines
to achieve the desired results.
 
Spray Application (General)
This is a high solids coating and may require adjustments in spray techniques. Wet film thickness is easily and quickly achieved. The following spray equipment has been found suitable and is available from manufacturers such as Binks, DeVilbiss and Graco.
Conventional Spray
Pressure pot equipped with dual regulators, 3/8” I.D. minimum material hose, with 50' maximum material hose .086” I.D. fluid tip and appropriate air cap.
Airless Spray
Pump Ratio: 30:1
GPM Output: 3.0 (min.)
Material Hose: 3/8” I.D. (min.)
Tip Size: .023-.035”
Output PSI: 2300-2500
Filter Size: 30 mesh
Teflon packings are recommended and available from the pump manufacturer.
Brush & Roller (General)
Recommended for touch up and striping of weld seams and hard-to-coat areas. Avoid excessive rebrushing or re-rolling.
Brush
Use a medium bristle brush.
Roller
Use a short-nap synthetic roller cover with phenolic core.
Mixing & Thinning
Mixing
Power mix until uniform in consistency.
Thinning
May be thinned up to 12 oz/gal (10%) with Thinner #10 if needed. When used directly to concrete, thinning is required on the first coat to provide adequate “soak-in”. Use of thinners other than those supplied or recommended by Carboline may adversely affect product performance and void product warranty, whether expressed or implied.
Cleanup & Safety
Cleanup
Use Thinner #2 or Xylene. In case of spillage, absorb and dispose of in accordance with local applicable regulations.
Safety
Read and follow all caution statements on this product data sheet and on the MSDS for this product. Employ normal workmanlike safety precautions. Hypersensitive persons should wear protective clothing, gloves and use protective cream on face, hands and all exposed areas.
Ventilation
Warning: Vapors may cause explosion. When usedin enclosed areas, thorough air circulation must be used during and after application until the coating is cured. The ventilation system should be capable of preventing the solvent vapor concentration from reaching the lower explosion limit for the solvents used. User should test and monitor exposure levels to insure all personnel are below guidelines. If not sure or if not able to monitor levels, use MSHA/NIOSH approved respirator.
Caution
This product contains flammable solvents. Keep away from sparks and open flames. All electrical equipment and installations should be made and grounded in accordance with the National Electric Code. In areas where explosion hazards exist, workmen should be required to use non-ferrous tools and wear conductive and non-sparking shoes.
MSDS
Application Conditions
Condition
Material
Surface
Ambient
Humidity
Normal
60 to 85°F
(16 to 29°C)
60 to 85°F
(16 to 29°C)
60 to 90°F
(16 to 32°C)
0-80%
Minimum
50°F (10°C)
50°F (10°C)
50°F (10°C)
0%
Maximum
90°F (32°C)
125°F (52°C)
110°F (43°C)
90%
Industry standards are for substrate temperatures to be above the dew point. This product simply requires the substrate temperature to be above the dew point. Condensation due to substrate temperatures below the dew point can cause flash rusting on prepared steel and interfere with proper adhesion to the substrate. Special application techniques may be required above or below normal application conditions.