This Clifton Steriliser features precision time and temperature control with programming options suitable for hot-air sterilisation of containers and instruments up to 250°C.
Sterilser features door locking and chamber vent closure when starting and during a sterilisation program.
Microprocessor control with auto diagnostics, digital LCD display to 0.1°C resolution, twenty program memory with event log of actual temperature and time data with RS232 interface.
Featuring wipe clean touch pad controls illuminated LCD display for viewing wide range of settings, programs, temperature and time values.
This model a 56 litre capacity is supplied with 2 wire shelves, with the option for additional wire or perforated shelves up to maximum capacity of 5.
The high grade 304 spec stainless steel chamber is sealed shut with a solid door. Alternative door configuration includes a window in the door allowing chamber observation.
Temperature
Range: ambient +5°C - 250°C.
Microprocessor control, dual pt100 temperature probes11.
Auto diagnostic system.
Digital LCD display to 0.1°C resolution.
Sensitivity @ 70°C ±0.3°C On wire shelf in middle chamber.
Uniformity @ 150°C ±0.7°C Measured in a vertical axis in the chamber using Wired Shelves.
Calibration Certificate @ 170°C.
Temperature and time programmable
Temperature and time programmable in two ways:
Six segment temperature-time profile with delay start13, heating up9, hold at set point12, each with timers from 1 minute to 99 hours.
Continuous mode at set point with either delay start 13, or timed up to 999 hours12.
Date and time setting, program can start unsupervised13.
Audible alarm and display, setting 0.5°C to 10°C about set point10.
Event log and program review temperature and time records.
Average minimum and maximum temperature values recorded for each segment of the program for reference and validation.
Forced air circulation with Fan speed regulation from 10 to 100%.
RS232 interface.
Over-temperature protection
Cass 1, thermal cut out 260°C 7 and separate element overheat protection.
Class 2, experiment/sample protection, adjustable setting above set point, heating switched off, audible and visual indication8.
Accessory options Class 3, temperature protection, self resetting cut outs.
Temperature sensor fail alarm11.
Power failure control with auto resume.
Interior and Case
Using a 304 spec stainless steel interior for long working lfe and easy cleaning.
Case construction stainless steel with powder painted exterior.
Sterilisers up to 112 litres are stackable.
|