Specifications |
Model 2532 |
Key Characteristics |
Bandwidth |
40 MHz |
Real time sample rate 2 channels interleaved |
500 MSa/s |
Equivalent sample rate |
50 GSa/s |
Rise time |
< 8.8ns |
Channels |
2 |
Lower frequency limit |
< 5Hz (at input BNC) |
Display |
Color LCD, 5.7 inch (145mm) diagonal |
Record Length* |
4000 points |
Vertical Resolution |
8 bit |
Vertical Sensitivity |
2mV - 5V/div |
DC gain accuracy |
±3.0% |
Maximum Input Voltage |
300 Vrms, CAT II (between signal and reference BNC connector) |
Position Range |
2mV - 100mV range: ±2V 200mV - 5V range: ±40V |
Time Base Range |
10 ns/div - 50 s/div |
Bandwidth Limit |
20 MHz |
Time Base Accuracy |
100 ppm |
Input Coupling |
AC, DC, GND |
Input Impedance |
1MΩ || 13Pf |
Vertical and Horizontal Zoom |
Vertically or horizontally expand or compress a live or stopped waveform |
I/O interface |
USB device port for connection to PC. (Requires included EasyScope Software for use) |
* The instrument displays 2500 points. 4000 points can be retrieved from internal memory with the included EasyScope application. This feature is supported for time base settings ranging from 2.5µs/Div - 50ms/Div (scan mode not active) |
Acquisition Modes |
Sample |
Display sample data only |
Peak Detect |
|
Average |
Waveform averaged, selectable from 4, 16, 32, 64, 128, 256 |
Scan Mode |
For time base settings 0.1s/div - 50s/div |
Trigger System |
Trigger Types |
Edge, Pulse Width, Video |
Trigger Modes |
Auto, Normal, Single |
Trigger Coupling |
AC, DC, LF reject, HF reject |
Trigger Source |
CH1, CH2, AC line, Ext, Ext/5 |
Holdoff range |
100ns - 1.5s |
Trigger Level Range |
CH1, CH2 |
±12 divisions from center of screen |
EXT |
±2.4V |
EXT/5 |
±12V |
|
Pulse Width Trigger |
Pulse Width Range |
20ns - 10s |
Trigger Condition |
(>, <, =) positive Pulse (>, <, =) negative Pulse |
|
Edge Trigger |
Trigger Polarity |
Rising and Falling Edge |
|
Video |
Supports formats PAL/SECAM, NTSC. Triggers on odd or even field, all lines or line number |
Cursors |
Types |
Amplitude, Time |
Measurements |
ΔV, ΔT, 1/ΔT |
Automatic Waveform Measurement |
Time |
Rise time, Fall Time, Cycle Frequency, Period, Positive Pulse width, Negative Pulse width |
Voltage |
MAX, MIN, Peak-Peak, Average, Vrms |
Frequency |
Hardware counter providing frequency readout of trigger source |
Readout resolution |
6 digits |
Range |
10Hz to max Bandwidth (DC Coupling) |
Supported signal types |
all trigger modes except pulse width trigger and Video Trigger |
|
Waveform Math |
Math functions |
FFT, add, subtract, multiply, divide |
FFT |
FFT Windows |
Hanning, Hamming, Blackman, Rectangular |
Sample size |
1024 points |
|
Autoset |
Single button automatic setup of both channels for vertical, horizontal and trigger systems |
XY Mode |
Bandwidth |
40 MHz |
Phase Error |
±3.0 degrees |
Display |
Display Mode |
1/4 VGA (320 × 240) Color LCD with adjustable contrast and inverse video |
Display types |
Point, Vector |
Persistence |
Off, 1s, 2s, 5s, infinite |
Waveform interpolation |
Sin(x)/x, Linear |
Format |
YT and XY |
Power Requirements |
Input Voltage |
100 - 240 VAC, CAT II, Auto selection |
Frequency |
45Hz to 440Hz |
Power |
50VA Max |
General |
Dimensions |
290mm (W) × 150mm (H) × 300mm (D) 11.4in (W) × 5.9in (H) × 11.8in (D) |
Weight |
4.6 kg (10 lbs) |
Environmental |
Temperature |
Operating: 0°C to +55°C Nonoperating: -40°C to +70°C |
Humidity |
Operating: 95%RH, 40°C Nonoperating: 90%RH, 65°C |
Altitude |
Operating to 4000m |
Pollution Degree |
Pollution degree 2 for indoor use only. |
Electromagnetic compatibility and Safety |
EMC |
This oscilloscope is in compliance with council EMC directive 2004/108/EC |
Safety |
EN61010-1:2001 |
Accessories |
Supplied |
User Manual, passive probe set (2 pieces), Power cord, USB interface cable, EasyScope Software Installation disk |
Optional |
PR 37A 10:1 Probe, PR 32A Demodulator Probe, PR 55 High Voltage Probe |