 Specifications  | 
 Model 2530  | 
| 
 Key Characteristics  | 
| 
 Bandwidth  | 
 25 MHz  | 
| 
 Real time sample rate, each channel  | 
 250 MSa/s  | 
| 
 Equivalent sample rate  | 
 50GSa/s  | 
| 
 Rise time  | 
 < 14ns  | 
| 
 Channels  | 
 2  | 
| 
 Lower frequency limit  | 
 < 5Hz (at input BNC)  | 
| 
 Display  | 
 Monochrome LCD, 5.7 inch (145mm) diagonal  | 
| 
 Record Length*  | 
 4000 points  | 
| 
 Vertical Resolution  | 
 8 bit  | 
| 
 Vertical Sensitivity  | 
 2mV - 5V/div  | 
| 
 DC gain accuracy  | 
 ±3.0%  | 
| 
 Maximum Input Voltage  | 
 300 Vrms, CAT II (between signal and reference BNC connector)  | 
| 
 Position Range  | 
 2mV - 100mV range: ±2V 200mV - 5V range: ±40V  | 
| 
 Time Base Range  | 
 2.5 ns/div - 50 s/divV  | 
| 
 Time Base Accuracy  | 
 100ppm  | 
| 
 Input Coupling  | 
 AC, DC, GND  | 
| 
 Input Impedance  | 
 1MΩ || 13Pf  | 
| 
 Vertical and Horizontal Zoom  | 
 Vertically or horizontally expand or compress a live or stopped waveform  | 
| 
 I/O interface  | 
 USB device port for connection to PC. (Requires included EasyScope Software for use)  | 
| 
 * The instrument displays 2500 points. 4000 points can be retrieved from internal memory with the included EasyScope application. This feature is supported for time base settings ranging from 2.5µs/Div - 50ms/Div (scan mode not active)  | 
| 
 Acquisition Modes  | 
| 
 Sample  | 
 Display sample data only  | 
| 
 Peak Detect  | 
    | 
| 
 Average  | 
 Waveform averaged, selectable from 4, 16, 32, 64, 128, 256  | 
| 
 Scan Mode  | 
 For time base settings 0.1s/div - 50s/div  | 
| 
 Trigger System  | 
| 
 Trigger Types  | 
 Edge, Pulse Width, Video  | 
| 
 Trigger Modes  | 
 Auto, Normal, Single  | 
| 
 Trigger Coupling  | 
 AC, DC, LF reject, HF reject  | 
| 
 Trigger Source  | 
 CH1, CH2, AC line, Ext, Ext/5  | 
| 
 Holdoff range  | 
 100ns - 1.5s  | 
| 
 Trigger Level Range   | 
 CH1, CH2  | 
 ±12 divisions from center of screen  |  
| 
 EXT  | 
 ±2.4V  |  
| 
 EXT/5  | 
 ±12V  |   
 | 
| 
 Pulse Width Trigger   | 
 Pulse Width Range  | 
 20ns - 10s  |  
| 
 Trigger Condition  | 
 (>, <, =) positive Pulse (>, <, =) negative Pulse  |   
 | 
| 
 Edge Trigger   | 
 Trigger Polarity  | 
 Rising and Falling Edge  |   
 | 
| 
 Video   | 
 Supports formats PAL/SECAM, NTSC. Triggers on odd or even field, all lines or line number  | 
| 
 Cursors  | 
| 
 Types  | 
 Amplitude, Time  | 
| 
 Measurements  | 
 ΔV, ΔT, 1/ΔT  | 
| 
 Automatic Waveform Measurement  | 
| 
 Time  | 
 Rise time, Fall Time, Cycle Frequency, Period, Positive Pulse width, Negative Pulse width  | 
| 
 Voltage  | 
 MAX, MIN, Peak-Peak, Average, Vrms  | 
| 
 Frequency  | 
 Hardware counter providing frequency readout of trigger source  |  
| 
 Readout resolution  | 
 6 digits  |  
| 
 Range  | 
 10Hz to max Bandwidth (DC Coupling)  |  
| 
 Supported signal types  | 
 all trigger modes except pulse width trigger and Video Trigger  |   
 | 
| 
 Waveform Math  | 
| 
 Math functions  | 
 FFT, add, subtract, multiply, divide  | 
| 
 FFT   | 
 FFT Windows  | 
 Hanning, Hamming, Blackman, Rectangular  |  
| 
 Sample size  | 
 1024 points  |   
 | 
| 
 Autoset  | 
| 
 Single button automatic setup of both channels for vertical, horizontal and trigger systems  | 
| 
 XY Mode  | 
| 
 Bandwidth  | 
 25 MHz  | 
| 
 Phase Error  | 
 ±3.0 degrees  | 
| 
 Display  | 
| 
 Display Mode  | 
 1/4 VGA (320 × 240) monochrome LCD with adjustable contrast and inverse video  | 
| 
 Display types  | 
 Point, Vector  | 
| 
 Persistence  | 
 Off, 1s, 2s, 5s, infinite  | 
| 
 Waveform interpolation  | 
 Sin(x)/x, Linear  | 
| 
 Format  | 
 YT and XY  | 
| 
 Power Requirements  | 
| 
 Input Voltage  | 
 100 - 240 VAC, CAT II, Auto selection  | 
| 
 Frequency  | 
 45Hz to 440Hz  | 
| 
 Power  | 
 50VA Max  | 
| 
 General  | 
| 
 Dimensions  | 
 290mm (W) × 150mm (H) × 300mm (D) 11.4in (W) × 5.9in (H) × 5.9in (D)  | 
| 
 Weight  | 
 4.6 kg (10 lbs)  | 
| 
 Environmental  | 
| 
 Temperature  | 
 Operating: 0°C to +55°C Nonoperating: -40°C to +70°C  | 
| 
 Humidity  | 
 Operating: 95%RH, 40°C Nonoperating: 90%RH, 65°C  | 
| 
 Altitude  | 
 Operating to 4000m  | 
| 
 Pollution Degree  | 
 Pollution degree 2 for indoor use only.  | 
| 
 Electromagnetic compatibility and Safety  | 
| 
 EMC  | 
 This oscilloscope is in compliance with council EMC directive 2004/108/EC  | 
| 
 Safety  | 
 EN61010-1:2001  | 
| 
 Accessories  | 
| 
 Supplied  | 
 User Manual, passive probe set (2 pieces), Power cord, USB interface cable, EasyScope Software Installation disk  | 
| 
 Optional  | 
 PR 37A 10:1 Probe, PR 32A Demodulator Probe, PR 55 High Voltage Probe  |