Selectable 120 000/40 000/4 000-count multimeter
Basic accuracy 0.012% V DC
Voltage masurement up to 1000V DC et 750V AC
Current measurement up to 12A
True RMS AC, AC+DC with 100KHz bandwidth
Resistance measurement up to 120Mohms
Frequency measurement from 5Hz to 1MHz
Selectable measurement rates
2 or 4 wires resistance measurements
dBm, %, MIN, MAX, HOLD, COMP functions
Dual display
RS-232 interface
GPIB version available (BK5482GPIB)
Specifications assumptions:
One-year calibration cycle. Operating temperature at 18 °C to 28°C (64.4°F to 82.4°F). Accuracy is expressed as: ± % of reading + digits) after 30 minutes warm-up. Temperature coefficient: Add ± [0. 15 x (the applicable accuracy)/°C] for 0°C to 18°C and 28°C to 50°C. Relative Humidity (RH) up to 80% for 0 °C to 28°C (75% RH for 12M Ohm and above ranges of resistance measurement); up to 70% for 28°C to 35°C; up to 50% for 35°C to 50°C All specifications are specified under single display mode in operation only.
Display Counts and Reading Rates
Full Scale Display Counts
Slow |
Medium |
Fast |
119,999 |
39,999 |
3,999 |
Reading Rates on Single Display (Readings/Sec)
Measurement Functions |
Slow |
Medium |
Fast |
DCV |
2 |
5 |
20 |
DCA |
2 |
5 |
20 |
Diode |
2 |
5 |
20 |
ACV |
2 |
4.2 |
20 |
ACA |
2 |
4.2 |
20 |
2-wires Ohm |
2 |
4 |
17 |
4-wires Ohm 4M Ohm/1.2M Ohm range and below |
0.6 |
0.8 |
0.9 |
4-wires Ohm 12M Ohm range and above |
1.4 |
1.7 |
1.9 |
Frequency |
1.2 |
1.7 |
2.4 |
ACV+DCV |
0.4 |
0.5 |
0.7 |
ACA+DCA |
0.4 |
0.5 |
0.7 |
Reading Rates on Dual Display (Readings/Sec)
Measurement Functions |
Slow |
Medium |
Fast |
DCV / ACV |
0.7 |
1.0 |
1.9 |
DCA / ACA |
0.7 |
1.0 |
1.9 |
DCV / DCA |
0.7 |
1.0 |
1.9 |
DCV / ACA |
0.2 |
0.2 |
0.5 |
ACV / ACA |
0.2 |
0.2 |
0.5 |
ACV / DCA |
0.7 |
1.0 |
1.9 |
ACV / Frequency |
0.5 |
0.7 |
1.1 |
ACA / Frequency |
0.6 |
0.8 |
1.3 |
ACV+DCV / DCV |
0.5 |
0.6 |
0.9 |
ACA+DCA / DCV |
0.1 |
0.2 |
0.4 |
ACA+DCA / ACV |
0.1 |
0.2 |
0.4 |
ACA+DCA / DCA |
0.5 |
0.6 |
0.9 |
dBm(ACV) / Reference Ohm |
2.1 |
4.2 |
11.9 |
dBm(ACV) / ACV |
0.7 |
1.0 |
1.7 |
dBm(ACV) / DCV |
0.6 |
1.0 |
1.7 |
dBm(ACV) / Frequency |
0.7 |
1.0 |
1.7 |
Note 1: Above table shows some common combinations and applications of using dual display.
Note 2: Using RS-232 or GPIB remote interface, the reading rate approximates to normal mode.
DC Voltage
Resolution, Full Scale Reading and Accuracy
Rate (1) |
Range |
Resolution |
Full Scale Reading |
Accuracy (1 year) |
Typical Input Impedance (4) |
S |
120mV 1.2V 12V 120V 1000V |
1uV 10uV 100uV 1mV 10mV |
119.999 1.19999 11.9999 119.999 1000.00(3) |
0.012% + 2 0.012% + 2 0.012% + 2 0.012% + 2 0.012% + 2 |
10.0M Ohm 10.0M Ohm 11.1M Ohm 10.1M Ohm 10.0M Ohm |
M |
400mV 4V 40V 400V 1000V |
10uV 100uV 1mV 10mV 100mV |
399.99 3.9999 39.999 399.99 1000.0(3) |
0.012% + 5 0.012% + 5 0.012% + 5 0.012% + 5 0.012% + 5 |
10.0M Ohm 11.1M Ohm 10.1M Ohm 10.0M Ohm 10.0M Ohm |
F |
400mV 4V 40V 400V 1000V |
100uV 1mV 10mV 100mV 1V |
399.9 3.999 39.99 399.9 1000(3) |
0.012% + 8 (2) 0.012% + 5 0.012% + 5 0.012% + 5 0.012% + 5 |
10.0M Ohm 11.1M Ohm 10.1M Ohm 10.0M Ohm 10.0M Ohm |
(1) Rate: S (Slow), M (Medium), and F (Fast). (2) Use relative (REL) modifier. (3) In Vdc 1000V range, 5% over-range (1050Vdc) is readable. (4) Input Impedance is in paralleled with capacitance <120pF. |
Maximum input voltage: 1000Vdc or peak ac on any range Response Time: Approximately 1.0 second when the displayed reading reaches 99.9% dc value of the tested input signal at the same range.
Note: When voltage (ac+dc) measurement function is selected, the Vdc input impedance is paralleled with an ac-coupled 1.1M Ohm ac divider.
Noise Rejection Ratio
Rate |
CMRR (1) |
NMRR (2) |
S / M / F |
>90dB at dc, 50/60Hz ± 0.1% (1k OhmUnbalanced) |
>50dB at 50/60Hz ± 0.1% |
(1) CMRR is the Common Mode Reject Ratio (2) NMRR is the Normal Mode Rejection Ratio |
AC Voltage (True RMS, AC Coupling Mode)
Resolution and Full Scale Reading
Range |
Resolution |
Full Scale Reading |
S |
M & F |
S |
M |
F |
S |
M |
F |
120mV 1.2V 12V 120V 750V |
400mV 4V 40V 400V 750V |
1uV 10uV 100uV 1mV 10mV |
10uV 100uV 1mV 10mV 100mV |
100uV 1mV 10mV 100mV 1V |
119.999 1.19999 11.9999 119.999 750.00 (1) |
399.99 3.9999 39.999 399.99 750.0 (1) |
399.9 3.999 39.99 399.9 750 (1) |
(1) In Vac 750V range, 5% over-range (787.5V rms) is readable |
Accuracy
Rate |
Range |
Accuracy (1 year) (1) |
20 to 45 Hz |
45 to 10k Hz |
10 to 30 kHz |
30 to 100 kHz |
S |
120.000mV 1.20000V 12.0000V 120.000V 750.00V |
1% + 5 1% + 5 1% + 5 1% + 5 (2) 1% + 5 (2) |
0.2% + 5 0.2% + 5 0.2% + 5 0.2% + 5 0.2% + 5 |
1.5% + 10 1% + 5 1% + 5 1% + 5 1% + 5 |
5% + 15 3% + 10 3% + 10 3% + 10 3% + 10 (3) |
M |
400.00mV 4.0000V 40.000V 400.00V 750.0V |
1% + 40 1% + 40 1% + 40 1% + 40 (2) 1% + 40 (2) |
0.2% + 40 0.2% + 40 0.2% + 40 0.2% + 40 0.2% + 40 |
1.5% + 80 1% + 40 1% + 40 1% + 40 1% + 40 |
5% + 120 3% + 80 3% + 80 3% + 80 3% + 80 (3) |
F |
400.0mV 4.000V 40.00V 400.0V 750V |
1% + 100 1% + 100 1% + 100 1% + 100 1% + 100 (2) |
0.2% + 100 0.2% + 100 0.2% + 100 0.2% + 100 0.2% + 100 |
1.5% + 300 1% + 100 1% + 100 1% + 100 1% + 100 |
5% + 300 3% + 200 3% + 200 3% + 200 3% + 200 (3) |
(1) Specified accuracy at input >5% of full scale |
(2) For input <200V rms |
(3) For input <500V rms |
|
|
|
|
|
|
|
Measurement method: True RMS Maximum Crest Factor: 3.0 at full scale Maximum input voltage: 750V rms, 1100V peak ac
2x107 V-Hz product on any range, normal mode input
1x106 V-Hz product on any range, common mode input Input Impedance: 1M Ohm in parallel with capacitance <120pF Response Time: Approximately 1.5 seconds when the displayed reading reaches 99.9% ac rms value of the tested input signal at the same range.
AC Voltage (True RMS, AC+DC Coupling Mode)
Resolution and Full Scale Reading
Range (1) |
Resolution |
Full Scale Reading |
S |
M & F |
S |
M |
F |
S |
M |
F |
120mV 1.2V 12V 120V 750V |
400mV 4V 40V 400V 750V |
1uV 10uV 100uV 1mV 10mV |
10uV 100uV 1mV 10mV 100mV |
100uV 1mV 10mV 100mV 1V |
119.999 1.19999 11.9999 119.999 750.00 (2) |
399.99 3.9999 39.999 399.99 750.0 (2) |
399.9 3.999 39.99 399.9 750 (2) |
(1) Vdc and Vac are automatically set at the same range (2) In Vac 750V range, 5% over-range (787.5V rms) is readable |
Accuracy
Rate |
Range |
Accuracy (1 year) (1) |
45 to 10k Hz |
10 to 30 kHz |
30 to 100 kHz |
S |
120.000mV 1.20000V 12.0000V 120.000V 750.00V |
0.2% + 7 0.2% + 7 0.2% + 7 0.2% + 7 0.2% + 7 |
1.5% + 12 1% + 7 1% + 7 1% + 7 1% + 7 |
5% + 18 3% + 12 3% + 12 3% + 12 3% + 12 (2) |
M |
400.00mV 4.0000V 40.000V 400.00V 750.0V |
0.2% + 45 0.2% + 43 0.2% + 43 0.2% + 43 0.2% + 43 |
1.5% + 83 1% + 43 1% + 43 1% + 43 1% + 43 |
5% + 125 3% + 83 3% + 83 3% + 83 3% + 83 (2) |
F |
400.0mV 4.000V 40.00V 400.0V 750V |
0.2% + 100 0.2% + 100 0.2% + 100 0.2% + 100 0.2% + 100 |
1.5% + 300 1% + 100 1% + 100 1% + 100 1% + 100 |
5% + 300 3% + 200 3% + 200 3% + 200 3% + 200 (2) |
(1) Specified accuracy at input >5% of full scale |
(2) For input <500V rms |
|
|
|
|
|
|
Measurement method: True RMS AC+DC Maximum Crest Factor: 3.0 at full scale Maximum input voltage: 750V rms, 1100V peak ac
2x107 V-Hz product on any range, normal mode input
1x106 V-Hz product on any range, common mode input Input Impedance: 1M Ohm in parallel with capacitance <120pF Response Time: Approximately 2.5 seconds when the displayed reading reaches 99.9% (ac+dc) rms value of the tested input signal at the same range.
DC Current
Rate |
Range |
Resolution |
Full Scale Reading |
Accuracy (1 year) |
Burden Voltage (1) & Shunt Resistor |
S |
12mA 120mA 1200mA 12A |
0.1uA 1mA 10mA 100mA |
11.9999 119.999 1199.99 11.9999 |
0.1% + 2 0.1% + 2 0.15% + 2 0.2% + 2 |
<0.15V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
M |
40mA 120mA 1200mA 12A |
1uA 10uA 100uA 1mA |
39.999 119.99 1199.9 11.999 |
0.1% + 6 0.1% + 3 0.15% + 3 0.2% + 3 |
<0.5V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
F |
40mA 120mA 1200mA 12A |
10uA 100uA 1mA 10mA |
39.99 119.9 1199 11.99 |
0.05% + 15 (2) 0.05% + 5 0.15% + 5 0.2% + 5 |
<0.5V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
(1) Typical at full scale reading and voltage across the input terminals (2) Use relative (REL) modifier |
Maximum Input and Overload Current Protection (for dc and ac current):
mA Input Terminal: 1200mA dc or ac rms and protected with 2A/250V, IEC-127 sheet 1 fast blow fuse;
12A input terminal: 10A dc or ac rms continuous, or 12A dc or ac rms for 30 seconds maximum and protected with 15A/500V, breaking capacity 10,000A fast blow fuse. Response Time: Approximately 1.0 second when the displayed reading reaches 99.9% dc value of the tested input signal at the same range.
AC Current (True RMS, AC Coupling Mode)
Resolution, Full Scale Reading and Burden Voltage
Rate |
Range |
Resolution |
Full Scale Reading |
Burden Voltage (1) & Shunt Resistor |
S |
12mA 120mA 1200mA 12A |
0.1uA 1uA 10uA 100uA |
11.9999 119.999 1199.99 11.9999 |
<0.15V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
M |
40mA 120mA 1200mA 12A |
1uA 10uA 100uA 1mA |
39.999 119.99 1199.9 11.999 |
<0.5V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
F |
40mA 120mA 1200mA 12A |
10uA 100uA 1mA 10mA |
39.99 119.9 1199 11.99 |
<0.5V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
(1) Typical at full scale reading and rms voltage across the input terminals |
Accuracy
Rate |
Range |
Accuracy (1 year) (1) |
20 to 45 Hz |
45 to 2k Hz |
2 to 10 kHz |
S |
12mA 120mA 1200mA 12A |
1.5% + 5 1.5% + 2 1.5% + 2 2% + 2 (<1.2A) |
0.5% + 5 0.5% + 2 0.5% + 2 1% + 2 |
2% + 10 2% + 5 2% + 5 - |
M |
40mA 120mA 1200mA 12A |
1.5% + 40 1.5% + 12 1.5% + 12 2% + 12 (<1.2A) |
0.5% + 40 0.5% + 12 0.5% + 12 1% + 12 |
2% + 80 2% + 30 2% + 30 - |
F |
40mA 120mA 1200mA 12A |
1.5% + 100 1.5% + 100 1.5% + 100 2% + 100 (<1.2A) |
0.5% + 100 0.5% + 100 0.5% + 100 1% + 100 |
2% + 200 2% + 200 2% + 200 - |
(1) Specified accuracy at input >5% of full scale |
Measurement method: True RMS Maximum Crest Factor: 3.0 at full scale Response Time: Approximately 1.5 seconds when the displayed reading reaches 99.9% ac rms value of the tested input signal at the same range.
AC Current (True RMS, AC+DC Coupling Mode)
Resolution, Full Scale Reading and Burden Voltage
Rate |
Range |
Resolution |
Full Scale Reading |
Burden Voltage (1) & Shunt Resistor |
S |
12mA 120mA 1200mA 12A |
0.1uA 1uA 10uA 100uA |
11.9999 119.999 1199.99 11.9999 |
<0.15V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
M |
40mA 120mA 1200mA 12A |
1uA 10uA 100uA 1mA |
39.999 119.99 1199.9 11.999 |
<0.5V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
F |
40mA 120mA 1200mA 12A |
10uA 100uA 1mA 10mA |
39.99 119.9 1199 11.99 |
<0.5V / 10 Ohm <1.5V / 10 Ohm <0.3V / 0.1 Ohm <0.6V / 0.01 Ohm |
(1) Typical at full scale reading and rms voltage across the input terminals |
Accuracy
Rate |
Range |
Accuracy (1 year) (1) |
45 to 2k Hz |
2 to 10 kHz |
S |
12mA 120mA 1200mA 12A |
0.5% + 7 0.5% + 4 0.5% + 4 1% + 4 |
2% + 12 2% + 7 2% + 7 - |
M |
40mA 120mA 1200mA 12A |
0.5% + 42 0.5% + 15 0.5% + 15 1% + 15 |
2% + 80 2% + 30 2% + 30 - |
F |
40mA 120mA 1200mA 12A |
0.5% + 100 0.5% + 100 0.5% + 100 1% + 100 |
2% + 200 2% + 200 2% + 200 - |
(1) Specified accuracy at input >5% of full scale |
Measurement range: Vdc and Vac are automatically set at the same range Measurement method: True RMS AC+DC Maximum Crest Factor: 3.0 at full scale Response Time: Approximately 2.5 seconds when the displayed reading reaches 99.9% (ac+dc) rms value of the tested input signal at the same range.
Resistance (2-wire Ohm and 4-wire Ohm)
Rate |
Range (1) |
Resolution |
Full Scale Reading |
Test Current |
Accuracy (1 year) |
2-wire |
4-wire |
S |
120 Ohm 1.2k Ohm 12k Ohm 120k Ohm 1.2M Ohm 12M Ohm 120M Ohm |
1m Ohm 10m Ohm 100m Ohm 1 Ohm 10 Ohm 100 Ohm 1k Ohm |
119.999 1.19999 11.9999 119.999 1.19999 11.9999 119.999 |
0.5mA 0.5mA 100mA 10mA 1mA 100nA 10nA |
0.1% + 2 (2) 0.08% + 2 0.06% + 2 0.06% + 2 0.15% + 2 1.5% + 2 5.0% + 2 |
0.05% + 2 0.05% + 2 0.05% + 2 0.05% + 2 0.15% + 2 1.5% + 2 5.0% + 2 |
M |
400 Ohm 4k Ohm 40k Ohm 400k Ohm 4M Ohm 40M Ohm 300M Ohm |
10m Ohm 100m Ohm 1 Ohm 10 Ohm 100 Ohm 1K Ohm 10k Ohm |
399.99 3.9999 39.999 399.99 3.9999 39.999 299.99 |
0.5mA 100mA 50mA 5mA 500nA 50nA 10nA |
0.1% + 5 (2) 0.08% + 3 (2) 0.06% + 3 0.06% + 3 0.15% + 3 1.5% + 3 5.0% + 5 |
0.05% + 5 (2) 0.05% + 3 0.05% + 3 0.05% + 3 0.15% + 3 1.5% + 3 5.0% + 5 |
F |
400 Ohm 4k Ohm 40k Ohm 400k Ohm 4M Ohm 40M Ohm 300M Ohm |
100m Ohm 1 Ohm 10 Ohm 100 Ohm 1k Ohm 10k Ohm 100k Ohm |
399.9 3.999 39.99 399.9 3.999 39.99 299.9 |
0.5mA 100mA 50mA 5mA 500nA 50nA 10nA |
0.1% + 8 (2) 0.08% + 5 (2) 0.06% + 5 (2) 0.06% + 5 0.06% + 5 0.3% + 5 3.0% + 8 |
0.05% + 8 (2) 0.05% + 5 (2) 0.05% + 5 0.05% + 5 0.05% + 5 0.3% + 5 3.0% + 8 |
(1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended to use a shielded test cable for measuring resistance above 120K Ohm. (2) Use relative (REL) modifier. |
Open Circuit Voltage: < +5.0V dc Zeroing error: 0.05 Ohm or less (excluding test lead resistances) in each range when REL modifier is used Response time: Approximately 1.5 seconds for 12M Ohm and ranges below 12M Ohm; approximately 5 seconds for 40M Ohm range; approximately 10 seconds for 120M Ohm ; approximately 25 seconds for 300M Ohm range. Maximum Input Protection: 500V dc or ac rms
Diode Test/Continuity
Rate |
Maximum Reading |
Resolution |
S |
1.19999V |
10mV |
M |
2.4999V |
100mV |
F |
2.499V |
1mV |
Open Circuit Voltage: < +5.0V dc Test Current: Approximately 0.5mA dc Audible Tone: Continuous beep for continuity and single tone for normal forward-biased diode or semiconductor junction Continuity level: Approximately below +50mVdc Maximum Input Protection: 500V dc or ac rms
Resistance/Continuity (2-wire)
Rate |
Range |
Resolution |
Maximum Reading |
Accuracy |
S |
120 Ohm |
1m Ohm |
119.999 |
0.1% + 2 (1) |
M |
400 Ohm |
10m Ohm |
399.99 |
0.1% + 5 (1) |
F |
400 Ohm |
100m Ohm |
399.9 |
0.1% + 8 (1) |
(1) Use relative (REL) modifier |
Open Circuit Voltage: < +5.0V dc Test Current: Approximately 0.5mA dc Audible Tone: Continuous beep for reading is less than 10 Ohm Zeroing error: 0.05 Ohm or less (excluding test lead resistances) in each range when REL modifier is used Maximum Input Protection: 500V dc or ac rms
Frequency
Resolution, Full Scale Reading and Accuracy
Range (Hz) |
Measurement Range (Hz) |
Resolution (Hz) |
Full Scale Reading |
Accuracy (1 year) (1) |
Input Sensitivity (Sine wave) |
1200 |
5 to 1200 |
10m |
1199.99 |
0.005 + 3 |
40mV rms |
12k |
10 to 12k |
100m |
11.9999 |
0.005 + 2 |
120k |
100 to 120k |
1 |
119.999 |
0.005 + 2 |
1M (2) |
1k to 1M |
10 |
1.19999 |
0.005 + 2 |
0.5V rms |
(1) Specified accuracy at input >5% of full scale (2) If tested frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed. |
Measurement method: True RMS Maximum Crest Factor: 3.0 at full scale Maximum input voltage: 750V rms, 1100V peak ac
2x107 V-Hz product on any range, normal mode input
1x106 V-Hz product on any range, common mode input Input Impedance: 1M Ohm in parallel with capacitance <120pF Response Time: Approximately 1.2 seconds when the displayed reading reaches 99.9% frequency value of the tested input signal at the same range.
dBm (decibel calculation)
Reference Impedance (1)
2 Ohm (2) 4 Ohm (2) 8 Ohm (2) 16 Ohm (2)
|
50 Ohm 75 Ohm 93 Ohm 110 Ohm 124 Ohm 125 Ohm |
135 Ohm 150 Ohm 250 Ohm 300 Ohm 500 Ohm 600 Ohm (3) |
800 Ohm 900 Ohm 1000 Ohm 1200 Ohm 8000 Ohm |
(1) Reference impedance is displayed on the secondary display (2) Reading displayed in watts (Audio Power) (3) Default reference impedance |
Range and Accuracy
Rate |
Voltage Range (1,2) |
Input Voltage |
dBm (3) Range @ 600 Ohm Ref |
Accuracy (dB) |
20 to 45 Hz |
45 to 10 kHz |
0 to 100 kHz |
S |
120mV 1.2V 12V 120V |
6mV ~ 120mV 120mV ~ 1.2V 1.2V ~ 12V 12V ~ 120V |
-42.20 ~ -16.20 -16.20 ~ 3.80 3.80 ~ 23.80 23.80 ~ 43.80 |
1.0 0.8 0.8 0.8 |
0.2 0.1 0.1 0.1 |
1.0 0.8 0.8 0.8 |
1000V (dc) 750V (ac) |
120V ~ 1000V 120V ~ 750V |
43.80 ~ 62.22 43.80 ~ 59.72 |
- |
1.0(4) |
- |
M & F |
400mV 4V 40V 400V |
20mV ~ 400mV 400mV ~ 4V 4V ~ 40V 40V ~ 400V |
-31.76 ~ -5.74 -5.74 ~ 14.26 14.26 ~ 34.26 34.26 ~ 54.26 |
1.0 0.8 0.8 0.8 |
0.2 0.1 0.1 0.1 |
1.0 0.8 0.8 0.8 |
1000V (dc) 750V (ac) |
400V ~ 1000V 400V ~ 750V |
54.26 ~ 62.22 54.26 ~ 59.72 |
- |
1.0(4) |
- |
(1) Auto-ranging is used when dBm function is selected (2) In Vac 750V range, 5% over-range is readable (3) Reading displayed in dB when REL modifier is used (4) For input voltage at frequency between 45Hz to 1kHz |
0dBm: 1 m Ohm @ 600 Ohm Reference Impedance Resolution: 0.01dB at slow and medium rate; 0.1dB at fast rate for all ranges. CMRR: > 90dB for dc signal Response Time: Same as ac voltage and ac current measurements.
A-3 General Specifications
General Items |
Specifications |
Ohmarm up time |
At least 30 minutes |
Temperature Coefficient |
Add 0.15 x (the applicable accuracy)/°C at 0°C to 18°C and 28°C to 50°C |
Operating Temperature |
0°C to 50°C (32°F to 122°F) |
Storage Temperature |
-20°C to 60°C |
Altitude |
Up to 2000 M |
Pollution Degree |
II |
Over-voltage Category |
CAT II-600V and CAT I-1000V |
Relative Humidity |
— Up to 80% for 0°C to 28°C (75% RH for 12M Ohm and above ranges of resistance measurement) — Up to 70%for 28°C to 35°C — Up to 50%for 35°C to 50°C |
Common Mode Voltage |
1000V dc or peak ac rms maximum between any input and earth ground |
Dimension |
Approx. 255(w) x 105(h) x 305(d) mm (with holsters) |
Ohmeight |
<3.0kgs |
Line Voltage |
100V / 120V / 220V / 240V ac ±10%, 50/60Hz, 16VA maximum |
Interface |
— RS-232 (DB-9, male connector) — Baud rates: 9600, 4800, 2400, 1200, 600, 300 — Data length: 7 or 8 bits — Parity: even / odd / none — Stop bit: 1 or 2 bits — Echo: on / off — Print mode: on / off |
Safety Requirement |
Designed in compliance with EN61010-1 (IEC1010-1) |
Installation Category |
CAT-I 750VAC/1000VDC or CAT-II 600V,Pollution Degree 2 Environment |
EMC Requirement |
Designed in compliance with EN61326-1. |
定货信息:
定货号
| 产品名称
| 规格配置
| 价格
|
DA-01057-00 | | 标准配置或电话咨询010-84851836 | 咨询 |